Vasai, Palghar, Maharashtra
GST No. 27AEZFS6417A1ZO
Call 08044564523 94% Response Rate
Send Enquiry
Product Brochure
| Model Name/Number | UV 2600 |
| Mobility | Benchtop |
| Optical System | Double Beam |
| Brand | Shimadzu |
| Spectral bandwidth | 0.1, 0.2, 0.5, 1, 2, 5 nm L2, L5 [Low stray-light mode] |
Features:
▪ The wavelength measurement range can be extended to include the near-infrared region by attaching an optional integrating sphere.
|
Wavelength range |
185 to 900 nm 220 to 1,400 nm when the ISR 2600Plus Integrating Sphere Attachment is used. |
|
Spectral bandwidth |
0.1, 0.2, 0.5, 1, 2, 5 nm L2, L5 [Low stray-light mode] |
|
Wavelength setting |
0.1 nm increments [1 nm increments when setting scanning range] |
|
Wavelength sampling pitch |
0.01 nm |
|
Wavelength accuracy |
±0.07 nm 656.1 nm D2, ±0.3 nm, All range |
|
Wavelength repeatability |
±0.01 nm |
|
Wavelength scanning speed |
Wavelength transfer: Approx.14,000 nm/min Wavelength scan rate: Approx.4,000 to 0.5 nm/min |
|
Lamp interchange wavelength |
Auto switching synchronized with wavelength; switching range selectable between 290 and 370 nm [0.1 nm increments] |
|
Stray light |
0.002% or less [220 nm, NaI] 0.00025% or less [340 nm, 370 nm, NaNO2] 0.2% or less [198 nm, KCl] |
|
Photometric system |
Double beam |
|
Photometric range |
−5 to 5 Abs [Display range ±10Abs, ±1012%] |
|
Photometric accuracy |
±0.0015 Abs [0.5 Abs] ±0.002 Abs [1.0 Abs] ±0.004 Abs [2.0 Abs] ±0.3%T Measured using NIST930/NIST1930 or equivalent filter |
|
Photometric repeatability |
±0.0002 Abs or less [0.5 Abs] ±0.0003 Abs or less [1 Abs] ±0.0004 Abs or less [2 Abs] ±0.1%T |
|
Baseline stability |
0.00015 Abs/h or less [700 nm] 1 hour after light source is turned ON |
|
Baseline flatness |
Within ±0.00015 Abs [200~860 nm] 1 hour after light source is turned ON |
|
Noise level |
0.000015 Abs or less [500 nm] |
|
Light source |
50 W halogen lamp, deuterium lamp Light source auto position adjustment built in |
|
Monochromator |
Czerny–Turner mounting Lo-Ray-Ligh™ grade blazed holographic grating Use grating Single monochromator |
|
Detector |
Photomultiplier |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Model Name/Number | UV 1900, UV-1900i |
| Mobility | Benchtop |
| Optical System | Double Beam |
| Spectral Bandwidth | 1 nm |
| Brand | Shimadzu |
| Wavelength Range | 190-1100 nm |
| Wavelength Accuracy | +-0.3 nm |
| Wavelength Repeatability | +-0.025 nm |
| Photometric Accuracy | +- 0.0015 |
| Lamp Type | Deuterium Lamp, Halogen Lamp |
|
Wavelength range |
190 to 1,100 nm |
|
Spectral bandwidth |
1 nm [190 to 1,100 nm] |
|
Wavelength setting |
0.1 nm increments [1 nm increments when setting scanning range] |
|
Wavelength accuracy |
± 0.05 nm at D2 peak 656.1 nm, ± 0.3 nm for entire range |
|
Wavelength repeatability |
± 0.025 nm |
|
Wavelength slew rate |
Approx. 29,000 nm/min |
|
Wavelength scanning speed |
3,000 to 2 nm/min 29,000 nm/min when survey scanning |
|
Lamp interchange wavelength |
Automatic interchange linked to wavelength. The interchange wavelength can be set freely in the range of 295 to 364 nm [0.1 nm increments]. |
|
Stray light |
Less than 0.004% at 220 nm [NaI] Less than 0.004% at 340 nm [NaNO2] Less than 0.15% at 198 nm [KCl] |
|
Photometric system |
Double beam optics |
|
Photometric range |
Absorbance: -4 to 4 Abs Transmittance: 0% to 400% |
|
Photometric accuracy |
± 0.0015 Abs at 0.5 Abs ± 0.002 Abs at 1.0 Abs ± 0.004 Abs at 2.0 Abs |
|
Photometric repeatability |
Less than ± 0.00002 Abs at 0.5 Abs Less than ± 0.00003 Abs at 1 Abs Less than ± 0.00007 Abs at 2 Abs |
|
Baseline stability |
Less than 0.0002 Abs/Hr [700 nm, one hour after light source turned ON] |
|
Baseline flatness |
Less than ± 0.0003 Abs [1,100 to 190 nm, one hour after light source turned ON] |
|
Noise level |
Less than 0.00001 Abs [700 nm] |
|
Light source |
20- W halogen lamp and deuterium lamp 21- Built-in light source auto position adjustment |
|
Monochromator |
LO-RAY-LIGH grade blazed holographic grating in Czerny-Turner mounting |
|
Detector |
Silicon photodiode |
|
Sample compartment |
Internal dimensions: W110 × D250 × H115 mm Distance between light beams: 100 mm |
|
PC compatibility |
LabSolutions UV-Vis software External control possible via USB. |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Light Source | Xenon Flash Lamp |
| Weight | 7.5 kg |
Features:
▪ Double Beam/Reference Cell
▪ 7-inch high-resolution touchscreen user interface
▪ Standard 8-position cell changer with switchable turret
▪ Onboard methods, reporting and data export
▪ Networking capable (Wi-Fi adaptor available)
▪ Room light resistance for 'open-lid' operation
▪ Sipper accessory
▪ Accommodates cells up to 100 mm pathlength
▪ 8-position cell changer with switchable turret
|
Baseline Flatness |
±0.002 A |
|
Detector Type |
Dual Silicon Photodiodes |
|
Display |
7 in. High Definition Color Touchscreen, Tiltable, 800 x 1280 pixels |
|
Dimensions (L x W x H) |
35.5 x 38.5 x 19.5 cm |
|
Spectral Bandwidth |
2 nm |
|
Wavelength Range |
190 to 1100 nm |
|
Drift |
(At 500 nm after 1 hour warmup) <0.0005 A/hr. |
|
Keypad |
Touchscreen |
|
Lamp Life |
> 5 years typical, 3 years guaranteed |
|
Optical Design |
±0.002A at 0.5A, ±0.004A at 1.0A, ±0.008 A at 2.0 A |
|
Photometric Display |
-3A to +5A |
|
Photometric Range |
–2A to +3.5A |
|
Photometric Repeatability |
±0.001 A at 1 A measured at 1.0 A at 546 nm |
|
Printer Included |
Snap-on printer available |
|
Scan Speed |
Slow, medium and fast - up to 1600 nm/min. |
|
Stray Light |
< 1.0%T 198 nm (KCl) , <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO2) |
|
Wavelength Accuracy |
±0.5 nm |
|
Wavelength Data Interval |
0.1 nm, 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
|
Wavelength Repeatability |
< ±0.2 nm |
|
Weight |
7.5 kg |
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 2 nm |
| Brand | Thermo Scientific |
| Model No / Item Code | Orion AquaMate 8100 |
| Lamp Type | Xenon Lamp |
Features:
▪ 260 Pre-Programmed Test Methods, And Flexibility To Program Your Own Custom Methods
▪ Round, Square And Rectangular Vial Holders
▪ Verification Testing Designed To Meet GLP And GMP Standards
▪ 7-Inch, High-Resolution Glove-Friendly Touchscreen
Specifications:
|
Optical Design |
Dual beam |
|
Spectral Bandwidth |
2.0 nm |
|
Light Source (Typical Lifetime) |
XENON flash lamp (5 years typical) |
|
Detector |
Dual silicon photodiodes |
|
Wavelength Range |
190 to 1100 nm |
|
Accuracy |
0.5 nm |
|
Repeatability |
<±0.2 nm |
|
Scanning Speed |
Slow, medium, fast (up to 1600 nm/min) |
|
Data Resolution |
0.2, 0.5, 1, 2, 5 nm |
|
Photometric Measurement Modes |
Absorbance, % transmittance, concentration |
|
Photometric Range |
–2A to +3.5A; <1000 %T to 0 %T; 9999 C |
|
Photometric Accuracy |
±0.002A at 0.5A, ±0.004A at 1.0A, ±0.008A at 2.0A |
|
Noise |
≤0.00020A at 0A at 260 and 500 nm |
|
Drift |
<0.0005 A/hr |
|
Stray Light |
< 1.0%T at 198 nm (KCl), <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO2) |
|
Display |
7-inch color touchscreen, fixed, high definition, 800 × 1280 pixels |
|
Keypad |
Glove compatible touchscreen |
|
Connectivity |
USB type A port for USB stick (front panel), |
|
Dimensions (LxWxH) |
5.5 × 38.5 × 19.5 cm |
|
Weight |
7.5 kg |
|
Power Requirements |
External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100–240 volts, 50–60 Hz |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 1 nm |
| Brand | Labman |
| Model No / Item Code | LUV2000T |
| Lamp Type | Tungsten Lamp, Deuterium Lamp |
| Usage / Application | Can Set Up Various Standard Curves As Per Customer And Find The Concentration Of Unknown Solutions |
| Warranty | 24 Months Guarantee |
| Voltage | 240 V |
| Frequency | 60 Hz |
| Country of Origin | Made in India |
| Type | UV Vis Spectrophotometer |
| Wavelength | 190 - 1100 nm |
|
Model |
LUV2000T |
|
Bandwidth |
1.0nm |
|
Optical System |
Double beam |
|
Wavelength Range |
190-1100nm |
|
Wavelength Accuracy |
±0.1nm[D2 656.1nm],±0.3 nm full range |
|
Wavelength Repeatability |
+0.1nm |
|
Photo-metric Range |
0-200%T. -0.3-3.0A, 0-9999C |
|
Photo-metric Accuracy |
±0.2T[0-100%T], ±0.002Abs[0-0.5Abs],±0.004Abs[0.5-1.0Abs] |
|
Photo metric Repeatability |
≤0.05%6T[0-100%6T], 0.001Abs[0-0.5Abs], 0.002Abs[0.5-1.0Abs] |
|
Stability |
+0.0004A/h @ 500nm |
|
Stray Light |
0.03%T @ 220 nm, 360 nm |
|
Cell Holder |
10mm each, Sample & Reference Cuvette Holder |
|
Focal Length |
10mm |
|
Light Source |
Tungsten Lamp & Deuterium lamp |
|
Resolution |
0.1nm |
|
Display |
Touchscreen 10-inches [800 x 480] HD TFT |
|
Memory |
32GB |
|
Detector |
Silicon Photo diode |
|
Control Mode |
Stand-alone system/PC software |
|
Baseline flatness |
±0.0008A/h |
|
Data Output |
USB |
|
Power Supply |
AC 220V/50Hz |
|
Dimension [L x W x H] |
630 x 430 x 210mm |
|
Weight |
28kg |
View Complete details
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Spectral Bandwidth | 1.0, 2.0, 4.0,5.0 nm [variable] |
| Mobility | Benchtop |
| Brand | Labman |
| Model No / Item Code | LUV-2100T |
Specifications:
|
Model |
LUV2100T |
|
Bandwidth |
1.0, 2.0, 4.0,5.0 nm [variable] |
|
Optical System |
Double beam |
|
Wavelength Range |
190-1100nm |
|
Wavelength Accuracy |
±0.1nm[D2 656.1nm],±0.3 nm full range |
|
Wavelength Repeatability |
+0.1nm |
|
Photo-metric Range |
0-200%T. -0.3-3.0A, 0-9999C |
|
Photo-metric Accuracy |
±0.2T[0-100%T], ±0.002Abs[0-0.5Abs],±0.004Abs[0.5-1.0Abs] |
|
Photo metric Repeatability |
≤0.05%6T[0-100%6T], 0.001Abs[0-0.5Abs], 0.002Abs[0.5-1.0Abs] |
|
Stability |
+0.0004A/h @ 500nm |
|
Stray Light |
0.03%T @ 220 nm, 360 nm |
|
Cell Holder |
10mm each, Sample & Reference Cuvette Holder |
|
Focal Length |
10mm |
|
Light Source |
Tungsten Lamp & Deuterium lamp |
|
Resolution |
0.1nm |
|
Display |
Touchscreen 10-inches [800 x 480] HD TFT |
|
Memory |
32GB |
|
Detector |
Silicon Photo diode |
|
Control Mode |
Stand-alone system/PC software |
|
Baseline flatness |
±0.0008A/h |
|
Data Output |
USB |
|
Power Supply |
AC 220V/50Hz |
|
Dimension [L x W x H] |
630 x 430 x 210mm |
|
Weight |
28kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Portable |
| Spectral Bandwidth | 1 nm |
| Brand | Labman |
| Detector | Silicon Photodiode |
| Lamp Type | Deuterium Lamp, Tungsten Halogen Lamp |
| Usage / Application | Multi functions operated directly on the spectrophotometer and display the test results curve and d |
| Warranty | 2 Years Guarantee |
| Voltage | 220 V |
| Frequency | 50 Hz |
| Country of Origin | Made in India |
| Type | UV Vis Spectrophotometer Double Beam |
| Wavelength | 190-1100nm |
|
Model |
LMSPUV1900 |
|
Sample Cell Holder |
10mm Cell Holder |
|
Bandwidth |
1nm |
|
Reference Cell Holder |
10 Cell Holder |
|
Make |
LABMAN |
|
Optical System |
Double Beam(1200 Lines/mm Grating) |
|
Wavelength Range |
190-1100nm |
|
Bandwidth |
1nm |
|
Wavelength Accuracy |
±0.3nm |
|
Wavelength Repeatability |
±0.2nm |
|
Scanning Speed |
Fast, Medium & Low |
|
Photometric Accuracy |
±0.3%T |
|
Photometric Repeatability |
0.2%T |
|
Photometric Range |
-0.3-3A,0-200%T,0-9999C |
|
Stability |
± 0.001 A/h @ 500nm |
|
Baseline Flatness |
±0.001A/h |
|
Noise |
±0.001A/h |
|
Stray Light |
<0.05%T @ 220nm,360nm |
|
Data Output Port |
USB |
|
Printer Port |
Parallel Port |
|
Display |
LCD |
|
Light Source |
D2 Lamp & Tungsten Halogen Lamp (W Lamp) |
|
Detector |
Silicon Photodiode |
|
Power Supply |
AC 220V,50/60Hz |
|
Dimension & Weight |
625x430x206 mm & 30kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Spectral Bandwidth | 1 nm |
| Mobility | Benchtop |
| Model No / Item Code | LMSPUV1908 |
| Brand | Labman |
| Lamp Type | Deuterium Lamp, Tungsten Halogen Lamp |
| Usage / Application | For Measuring Visible, Near-infrared And Near-ultraviolet Light |
| Warranty | 2 Year guarantee |
| Voltage | 240 V |
| Frequency | 50 Hz |
| Country of Origin | Made in India |
| Type | UV Vis Spectrophotometer |
| Wavelength | 190-1100nm |
|
Model |
LMSPUV1908 |
|
Sample Cell Holder |
8 Cell Holder Programmable 10mm |
|
Bandwidth |
1nm |
|
Reference Cell Holder |
10 Cell Holder |
|
Make |
LABMAN |
|
Optical System |
Double Beam(1200 Lines/mm Grating) |
|
Wavelength Range |
190-1100nm |
|
Bandwidth |
1nm |
|
Wavelength Accuracy |
±0.3nm |
|
Wavelength Repeatability |
±0.2nm |
|
Scanning Speed |
Fast, Medium & Low |
|
Photometric Accuracy |
±0.3%T |
|
Photometric Repeatability |
0.2%T |
|
Photometric Range |
-0.3-3A,0-200%T,0-9999C |
|
Stability |
± 0.001 A/h @ 500nm |
|
Baseline Flatness |
±0.001A/h |
|
Noise |
±0.001A/h |
|
Stray Light |
<0.05%T @ 220nm,360nm |
|
Data Output Port |
USB |
|
Printer Port |
Parallel Port |
|
Display |
LCD |
|
Light Source |
D2 Lamp & Tungsten Halogen Lamp (W Lamp) |
|
Detector |
Silicon Photodiode |
|
Power Supply |
AC 220V,50/60Hz |
|
Dimension & Weight |
625x430x206 mm & 30kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Portable |
| Spectral Bandwidth | 1 nm |
| Brand | Labman |
| Detector | Silicon Photodiode |
| Lamp Type | Tungsten Halogen Lamp, Deuterium Lamp |
| Usage / Application | For Measuring Visible, Near-infrared And Near-ultraviolet Light |
| Warranty | 2 Years Guarantee |
| Voltage | 240 V |
| Frequency | 50 Hz |
| Country of Origin | Made in India |
| Type | UV Vis Spectrophotometer |
| Wavelength | 190-1100 nm |
|
Model |
LMSPUV1928 |
|
Sample Cell Holder |
8cell holder programmable 10 mm |
|
Bandwidth |
1.0, 2.0, 4.0 nm (variable) |
|
Reference Cell Holder |
10 Cell Holder |
|
Make |
LABMAN |
|
Optical System |
Double Beam(1200 Lines/mm Grating) |
|
Wavelength Range |
190-1100nm |
|
Bandwidth |
1nm |
|
Wavelength Accuracy |
±0.3nm |
|
Wavelength Repeatability |
±0.2nm |
|
Scanning Speed |
Fast, Medium & Low |
|
Photometric Accuracy |
±0.3%T |
|
Photometric Repeatability |
0.2%T |
|
Photometric Range |
-0.3-3A,0-200%T,0-9999C |
|
Stability |
± 0.001 A/h @ 500nm |
|
Baseline Flatness |
±0.001A/h |
|
Noise |
±0.001A/h |
|
Stray Light |
<0.05%T @ 220nm,360nm |
|
Data Output Port |
USB |
|
Printer Port |
Parallel Port |
|
Display |
LCD |
|
Light Source |
D2 Lamp & Tungsten Halogen Lamp (W Lamp) |
|
Detector |
Silicon Photodiode |
|
Power Supply |
AC 220V,50/60Hz |
|
Dimension & Weight |
625x430x206 mm & 30kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Mobility | Benchtop |
| Model No / Item Code | LMSPUV1920 |
| Spectral Bandwidth | 1 nm |
| Brand | Labman |
| Lamp Type | Tungsten Halogen Lamp, Deuterium Lamp |
| Usage / Application | Measures A Substance's Light Absorption Using One Light Beam To Determine Its Concentration |
| Warranty | 2 Year Guarantee |
| Voltage | 220 V |
| Frequency | 60 Hz |
| Country of Origin | Made in India |
| Type | UV Vis Double Beam Spectrophotometer |
| Wavelength | 190-1100nm |
| Optical System | Single Beam |
|
Model |
LMSPUV1920 |
|
Sample Cell Holder |
10mm Cell Holder |
|
Bandwidth |
1.0, 2.0, 4.0 nm (variable) |
|
Reference Cell Holder |
10 Cell Holder |
|
Make |
LABMAN |
|
Optical System |
Double Beam(1200 Lines/mm Grating) |
|
Wavelength Range |
190-1100nm |
|
Bandwidth |
1nm |
|
Wavelength Accuracy |
±0.3nm |
|
Wavelength Repeatability |
±0.2nm |
|
Scanning Speed |
Fast, Medium & Low |
|
Photometric Accuracy |
±0.3%T |
|
Photometric Repeatability |
0.2%T |
|
Photometric Range |
-0.3-3A,0-200%T,0-9999C |
|
Stability |
± 0.001 A/h @ 500nm |
|
Baseline Flatness |
±0.001A/h |
|
Noise |
±0.001A/h |
|
Stray Light |
<0.05%T @ 220nm,360nm |
|
Data Output Port |
USB |
|
Printer Port |
Parallel Port |
|
Display |
LCD |
|
Light Source |
D2 Lamp & Tungsten Halogen Lamp (W Lamp) |
|
Detector |
Silicon Photodiode |
|
Power Supply |
AC 220V,50/60Hz |
|
Dimension & Weight |
625x430x206 mm & 30kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 1 nm |
| Brand | Lasany |
| Model No / Item Code | LI-2704 |
| Wavelength Accuracy | +- 0.5 nm |
| Wavelength Repeatability | +- 0.2 nm |
| Photometric Accuracy | +- 0.3% T |
| Lamp Type | Tungsten Lamp, Deuterium Lamp |
| Country of Origin | Made in India |
Features:
▪ Double beam optical system
▪ Low noise and Low stray light
▪ Large LCD display, can display curve
▪ Data and Curve can be stored in real-time
Specifications:
|
Wavelength Range |
190-1100nm |
|
Spectral Bandwidth |
1nm |
|
Optical System |
Double Beam, Blazed Holographic Grating [1200 lines/mm] |
|
Wavelength Accuracy |
±0.5nm |
|
Wavelength Repeatability |
≤0.2nm |
|
Wavelength Setting |
Auto, Resolution 0.1nm |
|
Photo-metric Range |
0~200%T, -4~4A, 0~9999C |
|
Photo-metric Accuracy |
±0.002 A [0~0.5A], ±0.003A [0.5~1A], ±0.3%T [0~100%T] |
|
Photo-metric Repeatability |
≤0.001 A [0~0.5A], ≤0.002A [0.5~1A], ≤0.2%T [0~100%T] |
|
Stray Light |
≤0.05%T[220/360nm] |
|
Scan Speed |
High, Medium, Low. Max.3200 nm/minute |
|
Baseline Flatness |
±0.0015A |
|
Stability |
±0.001A/h [500nm,0A] |
|
Noise |
≤0.2%T/3min [250/500nm,0%T]; ≤0.5%T/3min [250/500nm,100%T] |
|
Sample Compartment |
10mm Pathlength Cuvette |
|
Detector |
Silicon Photodiode |
|
Lamps |
Tungsten Lamp & Deuterium Lamp [Pre-aligned] |
|
Display |
Graphic LCD [320*240 Dots] |
|
Keypad |
30-key Alphanumeric Membrance Keypad |
|
Output Port |
USB Port |
|
Printer |
Mini Serial Printer; PC Printer |
|
PC Software |
UV Analyst Scanning Software |
|
Power Requirements |
AC 90-250V, 50/60Hz |
|
Dimension |
545x468x245mm |
|
Weight |
18kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 1 nm |
| Brand | Lasany |
| Model No / Item Code | LI-2700 |
| Wavelength Repeatability | +-0.1 nm |
| Photometric Accuracy | +- 0.3% T |
| Lamp Type | Tungsten Lamp, Deuterium Lamp |
| Country of Origin | Made in India |
Features:
▪ Maximum of 9 Wavelength & 1 samples can be measured at one time.
▪ Automatic change-over between T lamp & D2 lamp.
▪ Rich measurement methods : wavelength scan, time scan multi-wavelength determination,
▪ Data Output can be obtained via a printer port and a USB interface.
▪ PC controller measurement can be achieved for more accurate and flexible requirement.
Specifications:
|
Optical System |
Double Beam, Grating 1200 lines/mm |
|
Wavelength Range |
190nm - 1100nm |
|
Spectral Bandwidth |
1nm |
|
Wavelength Accuracy |
<=+/0.1nm [656.1nmD2],<=+/0.3nm[full wavelength Range] |
|
Wavelength Repeatability |
0.1nm |
|
Photometric Accuracy |
±0.3%T[0~100%T] |
|
Photometric Repeatability |
0.001Abs[0~0.5Abs] |
|
Photometric Range |
-3A~3A |
|
Stray Light |
<=0.02%T[220nm,nal,340nm NaMO2] |
|
Stability |
±0.0004 A/H@500nm |
|
Baseline Flatness |
±0.001A |
|
Noise |
0.0003 A/H |
|
Scanning Speed |
Fast, Mid, Slow |
|
Wavelength Setting |
AUTO |
|
Keyboard |
Membrane Keypad |
|
Light Source |
Deuterium & Tungsten Lamp |
|
Wavelength Resolution |
0.1nm |
|
Photometric Mode |
A,T,C |
|
Detector |
Silicon Photodiode |
|
Interface |
USB Portandparallelport [Printer] |
|
Power |
AC 220V/50Hz or AC 110V/60Hz |
|
Dimension |
590x460x220mm |
|
Weight |
25kg |
|
Drift |
<=+/0.0004A bs/h |
|
Cell Holder |
2 Cell Holder |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 0.5,1.0, 2.0, 4.0 nm |
| Brand | Antech |
| Model No / Item Code | AN-UV-7000N |
| Lamp Type | Deuterium Lamp |
Features:
▪ Equipped with USB port to connect to PC.
▪ Software comes standard with the instrument
▪ Multi functions like spectrum scanning, standard curve, kinetics, multi wavelength scanning, DNA/Protein testing can be operated directly on the Spectrophotometer and all corresponding curves and data can be displayed directly on the PC.
▪ All baseline, wavelength, dark current can be calibrated automatically to keep good running.
Specifications:
|
Optical System |
Double Beam [1200 Lines/mm Grating] |
|
Wavelength Range |
190-1100nm |
|
Bandwidth |
0.5,1.0, 2.0, 4.0 nm |
|
Wavelength Accuracy |
±0.1nm [D2 656.1], ± 0.3 nm @ all |
|
Wavelength Repeatability |
≤0.1nm |
|
Photometric Accuracy |
± 0.005 Abs |
|
Photometric Repeatability |
±0.002 Abs |
|
Photometric Range |
± 4 Abs |
|
Stability |
-0.3 - 3 A, 0-200% T, 0-9999 C |
|
Baseline Flatness |
± 0.0015 Abs |
|
Noise |
± 0.0005 Abs |
|
Stray Light |
≤0.03% @ 220nm, 360nm |
|
Data Output Port |
USB |
|
Printer Port |
Parallel Port |
|
Display |
320*240 Dots LCD |
|
Lamps |
D2 Lamp & W Lamp |
|
Detector |
Silicon Photodiode |
|
Power Requirements |
AC 220V/50Hz or 110V/60Hz |
|
Dimensions |
625 x 430 x 206 mm |
|
Weight |
32 kg |
View Complete details
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 2 nm |
| Brand | Lab India |
| Model No / Item Code | UV2000U |
Features:
▪ High performance fixed 2nm spectral bandwidth.
▪ Low stray light 0.05%T.
▪ Wavelength accuracy ± 0.5nm
|
Optical system |
Optical system Double beam with 1200 lines / mm |
|
Scan speed |
Select-able, better than 1600 nm |
|
Wavelength range |
190 -1100nm |
|
Wavelength accuracy |
±0.5nm |
|
Wavelength repeatability |
± 0.2nm |
|
Spectral bandwidth |
2nm |
|
Photo-metric mode |
Transmittance, Absorbance, Energy |
|
Photo-metric range |
-0.3 - 3.0Abs |
|
Photo-metric accuracy |
0.002A (0-0.5A), 0.004A (0.5 -1A) 0.3%T (0 -100%T) |
|
0.3%T (0 -100%T) 0.3%T (0 -100%T) |
0.3%T (0 -100%T) 0.3%T (0 -100%T) |
|
Photo-metric repeatability |
0.001A (0 - 0.5A), 0.002A (0.5 -1A) 0.15%T (0 -100%T) |
|
Photo-metric noise |
0.001A (500nm) 30min warm- |
|
Baseline flatness |
0.002A (200 -1000nm) |
|
Baseline stability |
0.001A/h (500nm,0Abs), 2hr warm-up |
|
Stray light |
≤0.05%T (220nm Nal, 340nm NaNO2) |
|
Standard Functionality |
Photo-metric Measurement (Quantitative, Multi-wavelength, Spectrum and Kinetic measurements) |
|
|
Spectrum & Kinetic by Software |
|
Optional Accessory |
Specular Reflection Accessory, Integrating Sphere 60mm / 100mm Automatic 8 Cell Changer, long path cell holder, Peltier Solid Sample holder etc. |
|
Detector |
Silicon photo diode |
|
Light source |
Light source Tungsten Halogen and Deuterium arc lamps |
|
Display |
Graphic LCD - 5 inch |
|
Printer |
Parallel Port |
|
PC Interface |
USB PORT |
View Complete details
Product Brochure
| Wavelength Range | 190 - 900nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 0.1 - 5.0 nm |
| Brand | Lab India |
| Model No / Item Code | UV3092 |
Features:
▪ Fully PC Controlled True Double beam UV Visible Spectrophotometer
Specifications:
|
Optical System |
True Double beam UV Visible Spectrophotometer sealed & quartz coated with Czerny-Turner monochromator |
|
Diffraction Grating |
1200 lines/nm |
|
Wavelength Range |
190 - 900nm |
|
Wavelength Accuracy |
± 0.1nm at 656.1nm & ± 0.3nm for entire range |
|
Wavelength Scan Rate |
4000 to 2nm/min and 6 nm/min with inter val of 0.05 nm by advance software |
|
Wavelength Slew Rate |
14000 nm/min |
|
Wavelength Resolution |
0.01 nm |
|
Spectral Bandwidth |
Continuous slit 0.1 - 5.0nm with 0.1nm inter val |
|
Resolution |
0.1 nm |
|
Photometric Mode |
Transmittance, Absorbance, Energy Concentration, All Using UVWin Sof tware |
|
Photometric Range |
- 4.0 - 4.0Abs |
|
Photometric Accuracy |
0.002A (0 - 0.5A), 0.004A (0.5 - 1.0A), 0.3%T (0 -100%T) |
|
Wavelength Repeatability |
± 0.05nm |
|
Photometric Reproducibility |
0.0001A |
|
Photometric Noise |
<0> |
|
Baseline Flatness |
± 0.0005 A / h at 500nm, after warm up |
|
Baseline Stability |
0.0005A/h (500nm, 0Abs), 1hr warm-up |
|
Stray light |
≤ 0.01 %T (220nm Nal, 340nm NaNO2) |
|
Detector |
Photo multiplier tube |
|
Light Source |
Tungsten Halogen and Deuterium arc lamps |
|
PC Interface |
RS232/USB |
|
Optional Accessory |
Specular Reflection Accessory, Integrating Sphere 60mm / 100mm Automatic 8 Cell Changer, long path cell holder, Peltier Solid Sample holder etc. |
|
Power Supply |
Switchable 120 - 230VAC 50 - 60Hz |
|
Weight |
43 Kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Brand | Lab India |
| Model No / Item Code | UV3000 |
| Wavelength Accuracy | +- 0.1 nm @656.0 nm D2, +- 0.3 nm (190-1100) |
| Wavelength Repeatability | +-0.1 nm |
| Lamp Type | Tungsten Lamp, Deuterium Lamp |
Features:
▪ Holographic grating greatly reducing stray light of the instrument and making the analysis more accurate.
▪ High degree of automation, the operator only needs to press keys twice when measuring ordinary samples.
Specifications:
|
Optics |
Double Beam with Automatic 8 Cell Charger |
|
Wavelength Range |
190-1100 nm |
|
Spectral Band Width |
0.5, 1, 2, 5 |
|
Wavelength Display |
0.01 nm |
|
Wavelength Setting |
0.05 nm |
|
Wavelength Accuracy |
± 0.1 nm @656.0 nm D2, ± 0.3 nm (190-1100) |
|
Wavelength Repeatability |
0.1 nm |
|
Stray Light |
0.03% @340 & 220 nm, 1% @198 nm for KCI |
|
Photometric Range |
-3 to 3 A |
|
Photometric Accuracy |
±0.002 A at 0.5, ±0.004 at 1 A |
|
Photometric Reproducibility |
0.001 A (0.5 A), 0.002 A (1A) |
|
Baseline Stability |
±0.0002 Abs |
|
Baseline Flatness |
±0.001 Abs |
|
Scan Speed |
5-3500 nm/min |
|
Slew Speed |
5000 nm/min |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 1 nm |
| Brand | Si |
| Model No / Item Code | Si-1300 : Double beam UV-Vis. Spectrophotometer |
| Wavelength Accuracy | +-0.3 nm |
| Wavelength Repeatability | +- 0.2 nm |
| Photometric Accuracy | +- 0.2% T |
| Lamp Type | Tungsten Lamp, Deuterium Lamp |
| Country of Origin | Made in India |
|
MODEL |
Si-1300 |
|
Spectral Bandwidth |
1nm |
|
Optical System |
Double Beam Grating 1200 lines/mm |
|
Wavelength Range |
190-1100 nm |
|
Wavelength Accuracy |
±0.3nm |
|
Wavelength Repeatability |
±0.2nm |
|
Photometric Range |
±0-200%T, -0.3~3A, 0-9999C |
|
Photometric Accuracy |
0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A) |
|
Photometric Repeatability |
≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A) |
|
Photometric Mode |
T, A, C, E |
|
Stray Light |
+0.03%T@220nm, 360nm |
|
Stability |
±0.0003A/h @ 500 nm |
|
Baseline Flatness |
±0.001A @ 500nm |
|
Noise |
0.001A@500nm |
|
Scanning Speed |
Fast, Medium, Low (Max. 3000nm/min) |
|
Wavelength Setting |
Automatic |
|
Display |
7" TFT Color Screen |
|
Light Source |
Deuterium & Tungsten lamp |
|
Detector |
Silicon Photodiode |
|
Cell Holder |
10mm single cell holder (sample & reference) |
|
Output |
USB,RS232C |
|
Power supply |
AC 220V/50Hz |
|
Pakcing Dimension (LxWx H) |
880 x 690 x 520 mm |
|
Gross Weight |
30kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 1/2/4/5 |
| Brand | Si |
| Model No / Item Code | Si-1400 - Double beam UV-Vis. Spectrophotometer |
| Wavelength Accuracy | +-0.3 nm |
| Wavelength Repeatability | +- 0.2 nm |
| Photometric Accuracy | +-0.2 nm |
| Lamp Type | Tungsten Lamp, Deuterium Lamp |
| Country of Origin | Made in India |
|
MODEL |
Si-1400 |
|
Spectral Bandwidth |
1/2/4/5 (variable) |
|
Optical System |
Double Beam Grating 1200 lines/mm |
|
Wavelength Range |
190-1100 nm |
|
Wavelength Accuracy |
±0.3nm |
|
Wavelength Repeatability |
±0.2nm |
|
Photometric Range |
±0-200%T, -0.3~3A, 0-9999C |
|
Photometric Accuracy |
0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A) |
|
Photometric Repeatability |
≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A) |
|
Photometric Mode |
T, A, C, E |
|
Stray Light |
+0.03%T@220nm, 360nm |
|
Stability |
±0.0003A/h @ 500 nm |
|
Baseline Flatness |
±0.001A @ 500nm |
|
Noise |
0.001A@500nm |
|
Scanning Speed |
Fast, Medium, Low (Max. 3000nm/min) |
|
Wavelength Setting |
Automatic |
|
Display |
7" TFT Color Screen |
|
Light Source |
Deuterium & Tungsten lamp |
|
Detector |
Silicon Photodiode |
|
Cell Holder |
10mm single cell holder (sample & reference) |
|
Output |
USB,RS232C |
|
Power supply |
AC 220V/50Hz |
|
Pakcing Dimension (LxWx H) |
880 x 690 x 520 mm |
|
Gross Weight |
30kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 1 nm |
| Brand | Si |
| Model No / Item Code | Si-1500 : Double Beam UV-Vis. Spectrophotometer |
| Wavelength Accuracy | +-0.3 nm |
| Wavelength Repeatability | +- 0.2 nm |
| Photometric Accuracy | +- 0.3% T |
| Lamp Type | Deuterium Lamp, Tungsten Halogen Lamp |
| Country of Origin | Made in India |
|
MODEL |
Si-1500 |
|
Bandwidth |
1nm |
|
Cell Holder |
Sample & Reference Cuvette Holder (10mm each) |
|
Optical System |
Double Beam(1200 Lines/mm Grating) |
|
Wavelength Range |
190-1100nm |
|
Wavelength Accuracy |
±0.3nm |
|
Wavelength Repeatability |
±0.2nm |
|
Scanning Speed |
Fast, Medium & Low |
|
Photometric Accuracy |
±0.3%T |
|
Photometric Repeatability |
+0.2%T |
|
Photometric Range |
-0.3-3A,0-200%T,0-9999C |
|
Stability |
± 0.001A/h @ 500nm |
|
Baseline Flatness |
± 0.001A/h |
|
Focal Length |
10mm |
|
Stray Light |
≤0.05%T @ 220nm,360nm |
|
Data Output Port |
USB Port |
|
Printer Port |
Parallel Port |
|
Display |
LCD |
|
Lamps |
D2 Lamp & Tungsten Halogen Lamp (W Lamp) |
|
Detector |
Silicon Photodiode |
|
Power Supply |
AC 220V / 50Hz |
|
Dimension (LxWxH) |
620x430x200 mm |
|
Gross Weight |
30kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 1 / 2 / 4 / 5 nm |
| Brand | Si |
| Model No / Item Code | Si-1600 |
| Lamp Type | Deuterium Lamp, Tungsten Lamp |
|
MODEL |
Si-1600 |
|
Bandwidth |
1 / 2 / 4 / 5 nm |
|
Cell Holder |
Sample & Reference Cuvette Holder (10mm each) |
|
Optical System |
Double Beam(1200 Lines/mm Grating) |
|
Wavelength Range |
190-1100nm |
|
Wavelength Accuracy |
±0.3nm |
|
Wavelength Repeatability |
±0.2nm |
|
Scanning Speed |
Fast, Medium & Low |
|
Photometric Accuracy |
±0.3%T |
|
Photometric Repeatability |
+0.2%T |
|
Photometric Range |
-0.3-3A,0-200%T,0-9999C |
|
Stability |
± 0.001A/h @ 500nm |
|
Baseline Flatness |
± 0.001A/h |
|
Focal Length |
10mm |
|
Stray Light |
≤0.05%T @ 220nm,360nm |
|
Data Output Port |
USB Port |
|
Printer Port |
Parallel Port |
|
Display |
LCD |
|
Lamps |
D2 Lamp & Tungsten Halogen Lamp (W Lamp) |
|
Detector |
Silicon Photodiode |
|
Power Supply |
AC 220V / 50Hz |
|
Dimension (LxWxH) |
620x430x200 mm |
|
Gross Weight |
30kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 0.5/1/1.5/2/4/5nm Variable |
| Brand | Lasany |
| Model No / Item Code | LI-2800 Ex |
| Lamp Type | Deuterium Lamp, Tungsten Lamp |
Features:
▪ Double beam ensure low drift, low noise and Low stray light
▪ High speed MCU, high precision AD, large storage capacity
▪ Large LCD display [320*240 Dots]
Specifications:
|
Wavelength Range |
190-1100nm |
|
Spectral Bandwidth |
0.5/1/1.5/2/4/5nm Variable |
|
Optical System |
Double Beam, Blazed Holographic Grating [1200 lines/mm] |
|
Wavelength Accuracy |
±0.5nm |
|
Wavelength Repeatability |
≤0.2nm |
|
Wavelength Setting |
Auto, Resolution 0.1nm |
|
Photometric Range |
0~200%T,-4~4A,0~9999C |
|
Photometric Accuracy |
±0.002 A [0~0.5A], ±0.003A [0.5~1A], ±0.3%T [0~100%T] |
|
Photometric Repeatability |
≤0.001 A [0~0.5A], ≤0.002A [0.5~1A], ≤0.2%T [0~100%T] |
|
Stray Light |
≤0.05%T[220/360nm] |
|
Scan Speed |
High, Medium, Low. Max.2000nm/minute |
|
Baseline Flatness |
±0.001A |
|
Stability |
±0.001A/h [500nm,0A] |
|
Noise |
≤0.2%T/3min [250/500nm,0%T]; ≤0.3%T/3min [250/500nm,100%T] |
|
Sample Compartment |
10mm Pathlength Cuvette |
|
Detector |
Silicon Photodiode |
|
Lamps |
Tungsten Lamp & Deuterium Lamp [Pre-aligned] |
|
Display |
Graphic LCD [320*240 Dots] |
|
Keypad |
30-key Alphanumeric Membrance Keypad |
|
Output Port |
USB Port |
|
Printer |
Mini Serial Printer; PC Printer |
|
PC Software |
PC Scanning Software |
|
Power Requirements |
AC 90-250V, 50/60Hz |
|
Dimension |
635x515x255mm |
|
Weight |
26kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 0.5/1/1.5/2/4/5nm Variable |
| Brand | Lasany |
| Model No / Item Code | LI-2800 Ex |
| Lamp Type | Tungsten Lamp, Deuterium Lamp |
Features:
▪ High speed MCU, high precision AD, large storage capacity
▪ Large LCD display [320*240 Dots]
▪ 1.0nm or variable Bandwidth meet Pharmacopoeia
Specifications:
|
Wavelength Range |
190-1100nm |
|
Spectral Bandwidth |
0.5/1/1.5/2/4/5nm Variable |
|
Optical System |
Double Beam, Blazed Holographic Grating [1200 lines/mm] |
|
Wavelength Accuracy |
±0.5nm |
|
Wavelength Repeatability |
≤0.2nm |
|
Wavelength Setting |
Auto, Resolution 0.1nm |
|
Photometric Range |
0~200%T,-4~4A,0~9999C |
|
Photometric Accuracy |
±0.002 A [0~0.5A], ±0.003A [0.5~1A], ±0.3%T [0~100%T] |
|
Photometric Repeatability |
≤0.001 A [0~0.5A], ≤0.002A [0.5~1A], ≤0.2%T [0~100%T] |
|
Stray Light |
≤0.05%T[220/360nm] |
|
Scan Speed |
High, Medium, Low. Max.2000nm/minute |
|
Baseline Flatness |
±0.001A |
|
Stability |
±0.001A/h [500nm,0A] |
|
Noise |
≤0.2%T/3min [250/500nm,0%T]; ≤0.3%T/3min [250/500nm,100%T] |
|
Sample Compartment |
10mm Pathlength Cuvette |
|
Detector |
Silicon Photodiode |
|
Lamps |
Tungsten Lamp & Deuterium Lamp [Pre-aligned] |
|
Display |
Graphic LCD [320*240 Dots] |
|
Keypad |
30-key Alphanumeric Membrance Keypad |
|
Output Port |
USB Port |
|
Printer |
Mini Serial Printer; PC Printer |
|
PC Software |
PC Scanning Software |
|
Power Requirements |
AC 90-250V, 50/60Hz |
|
Dimension |
635x515x255mm |
|
Weight |
26kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 0.5/1.0/2.0/4.0/5.O nm |
| Brand | EI |
| Model No / Item Code | 2377 |
| Lamp Type | Tungsten Lamp, Deuterium Lamp |
Features:
▪ Equipped with 5 Inches 320 x 240 dots graphical LCD.
▪ The grating having very high resolution of 1200 lines/mm ensures a narrow bandwidth.
▪ USB Interface.
▪ The instrument has sample storage memory and printer output port for printing of data with any dot matrix printer.
Specifications:
|
Modes |
Basic, Wavelength Scan, Multi Wavelength, Kinetics, Quantitative, DNA/Protein |
|
Wavelength Range |
190- 1100 nm |
|
Spectral Bandwidth [Variable] |
0.5/1.0/2.0/4.0/5.Onm |
|
Optical System |
Double Beam, Grating 1200 lines/mm |
|
Wavelength Accuracy |
± 0.3nm |
|
Wavelength Repeatability |
± 0.2 nm |
|
Scanning Speed |
HI, MED, LOW, MAX 3000 nm/min |
|
Photo-metric Accuracy |
± 0.3 %T or ± 0.002A/h@1 A |
|
Photo-metric Range |
0 - 200 %T, -0.3 to 3A, 0 - 9999 Cone. |
|
Stray Light |
< 0.05 %T @ 220nm & 340nm |
|
Stability |
± 0.001A/h @500 nm |
|
Display |
5 Inches 320 x 240 Dots Graphical LCD |
|
Baseline Flatness |
±0.001 A [200- 1000 nm] |
|
Sample Compartment |
Standard 8 cell with automatic cell changer -10 mm path-length. [50 mm & 100 mm path-length optional at extra cost] |
|
Light Source |
Halogen & Deuterium Lamps [Pre-Aligned] |
|
Output |
USB for PC Connectivity and Parallel Port for dot matrix printer |
|
Power |
230 V±10%AC, 50 Hz |
|
Dimensions [Lx Bx H] |
600 x 450 x 200 mm [Approx.] |
|
Weight |
22 Kg. [Approx.] |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 1 nm |
| Brand | Lasany |
| Model No / Item Code | LI-2802R |
| Lamp Type | Tungsten Lamp, Deuterium Lamp |
Features:
▪ Wide Wavelength range, satisfying requirements of various fields.
▪ Maximum of 9 Wavelength & 8 samples can be measured at one time.
▪ Automatic 10mm 8-cell holder.
▪ Data Output can be obtained via a printer port and a USB interface.
▪ PC controller measurement can be achieved for more accurate and flexible requirement.
Specifications:
|
Optical System |
Double Beam, Grating 1200 lines/mm |
|
Wavelength Range |
190nm - 1100nm |
|
Spectral Bandwidth |
1nm |
|
Wavelength Accuracy |
<=+/0.1nm [656.1nmD2],<=+/0.3nm[full wavelength Range] |
|
Wavelength Repeatability |
0.1nm |
|
Photo-metric Accuracy |
±0.3%T[0~100%T] |
|
Photo-metric Repeatability |
0.001Abs[0~0.5Abs] |
|
Photo-metric Range |
-3A~3A |
|
Stray Light |
<=0.02%T[220nm,nal,340nm NaMO2] |
|
Stability |
±0.0004 A/H@500nm |
|
Baseline Flatness |
±0.001A |
|
Noise |
0.0003 A/H |
|
Scanning Speed |
Fast, Mid, Slow |
|
Wavelength Setting |
AUTO |
|
Keyboard |
Membrane Keypad |
|
Light Source |
Deuterium & Tungsten Lamp |
|
Wavelength Resolution |
0.1nm |
|
Photometric Mode |
A,T,C |
|
Detector |
Imported Silicon Photo-diode |
|
Interface |
USB Port and parallel port [Printer] |
|
Power |
AC 220V/50Hz or AC 110V/60Hz |
|
Dimension |
590x460x220mm |
|
Weight |
25kg |
|
Drift |
<=+/0.0004A bs/h |
|
Cell Holder |
8 Cell Holder |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 1 nm |
| Brand | Lasany |
| Model No / Item Code | LI-2702 |
| Lamp Type | Deuterium Lamp, Tungsten Lamp |
Functions:
▪ Photo-metric: T%, Abs
▪ Quantitative: Standard Curve
▪ System Utility
▪ WL Scan [Spectrum Scan]
▪ Time Scan [Kinetics]
▪ DNA/Protein Test
Specifications:
|
Wavelength Range |
1nm |
|
Spectral Bandwidth |
Double Beam, Blazed Holographic Grating [1200 lines/mm] |
|
Optical System |
±0.5nm |
|
Wavelength Accuracy |
≤0.2nm |
|
Wavelength Repeatability |
Auto, Resolution 0.1nm |
|
Wavelength Setting |
0~200%T, -4~4A, 0~9999C |
|
Photo-metric Range |
±0.002 A [0~0.5A], ±0.003A [0.5~1A], ±0.3%T [0~100%T] |
|
Photo-metric Accuracy |
≤0.001 A [0~0.5A], ≤0.002A [0.5~1A], ≤0.2%T [0~100%T] |
|
Photo metric Repeatability |
≤0.05%T[220/360nm] |
|
Stray Light |
High, Medium, Low. Max.2000nm/minute |
|
Scan Speed |
±0.0015A |
|
Baseline Flatness Stability |
±0.001A/h [500nm,0A] |
|
Noise |
≤0.2%T/3min [250/500nm,0%T]; ≤0.5%T/3min [250/500nm,100%T] |
|
Sample Compartment |
10mm Path length Cuvette |
|
Detector |
Silicon Photodiode |
|
Lamps Output Port |
Tungsten Lamp & Deuterium Lamp [Pre-aligned] |
|
Printer |
USB Port |
|
PC Software |
Mini Serial Printer; PC Printer |
|
Power Requirements |
AC 90-250V, 50/60Hz |
|
Dimension |
545x468x245mm |
|
Weight |
18KG |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Model No / Item Code | Model 108 |
| Wavelength Range | 200 to 900 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Brand | Systronics |
| Spectral Bandwidth | 0.5 nm |
| Lamp Type | Tungsten Halogen Lamp, Deuterium Lamp |
Features:
▪ High resolution, reliable, single beam, manual
▪ Digital Wavelength with 0.1 nm increments
▪ 200 – 900 nm Range
▪ 0.5 nm Bandwidth
▪ Wide range, low noise Photo multiplier tube [PMT] detector
▪ Manual 4 position sample changer
▪ Single Position 20/50 mm Cuvette Holder [Optional]
▪
Specifications:
|
Optics |
Complete mirror optics with 1200 grooves/mm grating Czerny-Turner mount |
|
Wavelength Range |
200 to 900 nm [with Spl. PMT] 200 to 700 nm [with Std. PMT] |
|
Readout |
Electronic Digital counter 0.1 nm increments |
|
Accuracy |
± 0.5 nm |
|
Repeatability |
± 0.2 nm |
|
Spectral Bandwidth |
0.5 nm [constant throughout the spectral range] |
|
Photo-metric Range [Digital] |
0 to 2.000 Abs 0-1999 concentration units 0-100% transmission |
|
Accuracy |
± 0.005 Abs at 1 Abs |
|
Repeatability |
± 0.002 Abs at 1 Abs |
|
Stray Light |
Less than 0.1% at 220 nm & 370 nm |
|
Source |
•Tungsten-Halogen lamp •Deuterium lamp |
|
Detector |
Wide range, low noise PMT |
|
Filters |
Built - in filter wheel with four filters |
|
Sample Holder |
Manual 4-position sample changer for 10mm cuvettes [cells] |
|
Power |
230V ± 10%, 50Hz, 200VA |
|
Dimensions |
800 [W] x 400 [D] x 300 [H] mm |
|
Weight |
32 kg. [Approx] |
|
Accessories |
2 matched 10mm path length quartz cuvette [cells] |
|
Optional Accessories |
Single Position 20/50 mm Cuvette Holder [Factory Installed] |