Vasai, Palghar, Maharashtra
GST No. 27AEZFS6417A1ZO
Call 08044564523 94% Response Rate
Send Enquiry
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Single Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 2 nm |
| Brand | Labman |
| Model No / Item Code | LUV1100T |
| Lamp Type | Tungsten Lamp, Deuterium Lamp |
| Usage / Application | For Measuring Visible, Near-infrared And Near-ultraviolet Light |
| Warranty | 2 Year Guarantee |
| Voltage | 240 V |
| Frequency | 50 Hz |
| Country of Origin | Made in India |
| Type | UV Vis Spectrophotometer |
| Wavelength | 190-1100 nm |
|
MODEL |
LUV1100T |
|
Bandwidth |
2.0nm |
|
Make |
LABMAN |
|
Optical System |
Single beam |
|
Wavelength Range |
190-1100nm |
|
Wavelength Accuracy |
±0.5nm |
|
Wavelength Repeatability |
+0.2nm |
|
Photometric Range |
0-200%T. -0.3-3.0A, 0-9999C |
|
Photometric Accuracy |
±0.2T(0-100%T), ±0.002Abs(0-0.5Abs),±0.004Abs(0.5-1 .OAbs ) |
|
Photometric Repeatability |
<0.1%T(0-100%T), 0.001 Abs(0-0.5Abs), 0.002Abs(0.5-1.0Abs) |
|
Stability |
+0.001 A/h @ 500nm |
|
Stray Light |
0.05%T @ 220 nm, 360 nm |
|
Cell Holder |
10mm each, Sample & Reference Cuvette Holder |
|
Focal Length |
10mm |
|
Light Source |
Tungsten Lamp & Deuterium lamp |
|
Resolution |
0.1nm |
|
Display |
Touchscreen 10-inches (800 x 480) HD TFT |
|
Memory |
32GB |
|
Detector |
Silicon Photodiode |
|
Control Mode |
Stand-alone system/PC software |
|
Baseline flatness |
±0.001A/h |
|
Data Output |
USB |
|
Power Supply |
AC 220V,50/60Hz |
|
Dimension (L x W x H) |
630 x 430 x 210mm |
|
Weight |
20kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Single Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 2 nm |
| Model No / Item Code | LMSPUV1200 |
| Brand | Labman |
Features:
▪ Users set wavelength automatically through arrow keys to avoid operation errors.
▪ Equipped with USB port to connect with a PC to display spectrum scanning, kinetics and multi wavelength testing results on the screen through the optional software.
▪ Tungsten lamp & Deuterium lamp can be turned on/off individually to extend shelf life
▪ Large sample compartment, it can accommodate 5-100mm path length cuvette with optional holders
Specifications:
|
Make |
LABMAN |
|
Wavelength Range |
190-1100nm |
|
Bandwidth |
2nm |
|
Optical System |
Single Beam, Grating 1200 lines / mm |
|
Wavelength Accuracy |
0.8nm |
|
Wavelength Repeatability |
0.2nm |
|
Wavelength Setting |
Auto |
|
Photo-metric Accuracy |
0.3%T |
|
Photo-metric Repeatability |
0.2%T |
|
Photo-metric Range |
-0.3-3A,0-200%T |
|
Stability |
0.001A/h @ 500nm |
|
Baseline Flatness |
0.002A/h |
|
Stray Light |
0.05 % T |
|
Data Output |
USB |
|
Printer Port |
Parallel Port |
|
Display |
LCD |
|
Cell Holder |
10 mm 4 position cuvette holder |
|
Lamps |
D2 Lamp & Tungsten Halogen Lamp [ W Lamp ] |
|
Detector |
Silicon Photo diode |
|
Power Supply |
AC 220V/50Hz |
|
Dimension [LxWxH] mm |
460x360x225mm |
|
Weight |
18kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1000nm |
| Optical System | Single Beam |
| Mobility | Benchtop |
| Model No / Item Code | LMSPUV1000B |
| Spectral Bandwidth | 2 nm |
| Brand | Labman |
| Lamp Type | Tungsten Halogen Lamp, Deuterium Lamp |
| Usage / Application | LMSPUV1000B can set up various standard curves according to customer's solutions |
| Warranty | 2 Years Guarantee |
| Voltage | 240 V |
| Frequency | 50 Hz |
| Country of Origin | Made in India |
| Type | UV Vis Spectrophotometer |
| Wavelength | 190-1000nm |
|
Model |
LMSPUV1000B |
|
Make |
LABMAN |
|
Optical System |
Single beam, Grating 1200 lines/mm |
|
Wavelength Range |
190-1000nm |
|
Bandwidth |
2nm |
|
Wavelength Accuracy |
±1nm |
|
Wavelength Repeatability |
±0.5nm |
|
Wavelength Setting |
Automatic. |
|
Photometric Accuracy |
±0.5%T |
|
Photometric Repeatability |
±0.3%T |
|
Photometric Range |
-0.3-3A,0-200%T |
|
Stray Light |
<0.3%T |
|
Stability |
± 0.002A/h @ 500nm |
|
Display |
LCD |
|
Detector |
Silicon Photodiode |
|
Standard Cell Holder |
4-position 10mm cell holder |
|
Light Source |
D2 lamp & Tungsten Halogen Lamp ( W Lamp) |
|
Output |
USB Port & Parallel Port(Printer) |
|
Power Supply |
AC 220V,50/60Hz |
|
Dimension (LxWxH) mm |
490 x 370 x 220 |
|
Weight |
15kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Single Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 2 nm |
| Brand | Si |
| Model No / Item Code | Si-700 : UV-Vis. Single Beam Spectrophotometer |
| Wavelength Accuracy | +- 0.5 nm |
| Wavelength Repeatability | +- 0.2 nm |
| Photometric Accuracy | +-0.5% T |
| Lamp Type | Tungsten Lamp, Deuterium Lamp |
| Country of Origin | Made in India |
|
PRODUCT NAME |
UV-VIS. SINGLE BEAM SPECTROPHOTOMETER |
|
MODEL |
Si-700 |
|
Spectral Bandwidth |
2nm |
|
Optical System |
Single Beam, Grating 1200 lines/mm |
|
Wavelength Range |
190-1100nm |
|
Wavelength Accuracy |
± 0.5 nm |
|
Wavelength Repeatability |
± 0.2 nm |
|
Photometric Range |
0-200%T, -0.3~3A, 0-9999C |
|
Photometric Accuracy |
± 0.5%T |
|
Photometric Repeatability |
± 0.2%T |
|
Photometric Mode |
T, A, C, E |
|
Stray Light |
± 0.1%T |
|
Stability |
± 0.0002A/h @500nm |
|
Baseline Flatness |
0.002 A |
|
Noise |
± 0.001 A |
|
Wavelength Setting |
Auto |
|
Display |
128 x 64 LCD |
|
Light Source |
Deuterium & Tungsten lamp |
|
Detector |
Silicon Photodiode |
|
Cell Holder |
4 position 10mm cell holder |
|
Output |
RS232C |
|
Power supply |
AC 220V/50Hz |
|
Packing Dimension (LxWxH) |
700 x 580x 340mm |
|
Gross Weight |
20kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Single Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 2 nm |
| Brand | Si |
| Model No / Item Code | Si-500 : UV-Vis. Single Beam Spectrophotometer |
| Wavelength Accuracy | +- 2 nm |
| Wavelength Repeatability | +-1 nm |
| Photometric Accuracy | +-0.5% T |
| Lamp Type | Tungsten Lamp, Deuterium Lamp |
Features:
|
PRODUCT NAME |
UV-VIS. SINGLE BEAM SPECTROPHOTOMETER |
|
MODEL |
Si-500 |
|
Wavelength Range |
190-1100nm |
|
Spectral Bandwidth |
2nm |
|
Light Source |
Deuterium & Tungsten lamp |
|
Optical System |
Single Beam, Grating 1200 lines/mm |
|
Wavelength Accuracy |
+ 2 nm |
|
Wavelength Repeatability |
+ 1nm |
|
Photometric Accuracy |
+ 0.5%T |
|
Photometric Repeatability |
+ 0.2%T |
|
Photometric Mode |
T, A, C |
|
Stray light |
0.15%T @500nm |
|
Stability |
0.002 A@500nm |
|
Wavelength Setting |
Manual |
|
Display |
70 x 40mm blue lightLCD |
|
Detector |
Silicon Photodiode |
|
Cell Holder |
4 position 10mm cell holder |
|
Output |
RS232C |
|
Power supply |
AC 220V/50Hz |
|
Packing Dimension (LxWxH) |
520 x 450 x 320mm |
|
Gross Weight |
10kg |
|
|
|
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1000 nm |
| Optical System | Single Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 2 nm |
| Brand | Si |
| Model No / Item Code | Si-600 |
| Wavelength Accuracy | +-1.0 nm |
| Wavelength Repeatability | +- 0.5 nm |
| Photometric Accuracy | +-0.5% T |
| Lamp Type | Tungsten Lamp, Deuterium Lamp |
| Country of Origin | Made in India |
|
PRODUCT NAME |
UV-VIS. SINGLE BEAM SPECTROPHOTOMETER |
|
MODEL |
Si-600 |
|
Optical System |
Single Beam, Grating 1200 lines/mm |
|
Spectral Bandwidth |
2 nm |
|
Wavelength Range |
190-1000nm |
|
Wavelength Accuracy |
± 1nm |
|
Wavelength Repeatability |
+ 0.5nm |
|
Photometric Range |
0-200%T, -0.3~3A, 0-9999C |
|
Photometric Accuracy |
± 0.5%T |
|
Photometric Repeatability |
± 0.3%T |
|
Photometric Mode |
T, A, C, E |
|
Stray light |
± 0.3%T |
|
Stability |
± 0.002A/h @500nm |
|
Baseline Flatness |
±0.002 A |
|
Noise |
±0.001 A |
|
Wavelength Setting |
Auto |
|
Display |
128 x 64 LCD |
|
Light Source |
Deuterium & Tungsten lamp |
|
Detector |
Silicon Photodiode |
|
Cell Holder |
4 position 10mm cell holder |
|
Output |
RS232C |
|
Power supply |
AC 220V/50Hz |
|
Packing Dimension (LxWxH) |
700 x 580 x 340mm |
|
Gross Weight |
19kg |
|
|
|
View Complete details
Product Brochure
| Wavelength Range | 195 nm - 1020 nm |
| Optical System | Single Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 2 nm |
| Brand | Lasany |
| Model No / Item Code | LI-285 |
Specifications:
|
Optical system: |
CT grating monochromator |
|
Wavelength range: |
195 nm - 1020nm |
|
Wavelength accuracy: |
+/- 2 nm |
|
Spectral bandwidth |
2nm |
|
Wavelength repeatability: |
1 nm |
|
Stray light: |
<= 0.3%T @220nm |
|
Photo-metric accuracy: |
+/- 0.5%T |
|
Photo-metric repeatability: |
0.2%T |
|
Stability: |
+/-0.004 A/h @500nm |
|
Work Pattern: |
T, A, C |
|
Display area: |
0- 200%T, - 0.3 - 3A |
|
Display modes: |
4 LCD |
|
Zero setting: |
Automatic |
|
Weight: |
12 kg |
View Complete details
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Single Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 1 nm |
| Brand | Lasany |
| Model No / Item Code | LI-295 |
Features:
▪ Large LCD screen (128*64) Dots.
▪ Can display and save 50 groups of data, 5 groups per screen.
▪ Data can be restored after a sudden power cut.
▪ Auto setting Wavelength
▪ Tungsten lamp & deuterium lamp can be turned on/off individually to extend lifetime.
▪ Automatic WL. Calibration and dark current getting.
▪ With scanning software.
Specifications:
|
Wavelength Range |
190-1100 nm |
|
Wavelength Accuracy |
+-1.0 nm |
|
Wavelength Repeatability |
0.5nm |
|
Photo-metric Range |
-0.3-3A,0-200%T |
|
Photo-metric Repeatability |
+- 0.3% T |
|
Stray Light |
<0.3%T |
|
Display |
128 x 64 Dots LCD |
|
Weight |
2 kg |
|
Power Requirements |
AC 85 ~ 250V |
|
Dimension |
420 x 280 x 180 mm |
|
Wavelength Setting |
Auto |
|
Bandwidth |
2 nm |
|
Model No |
LI-295 |
|
Optional System |
Single - Beam, Grating |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-1100 nm |
| Optical System | Single Beam |
| Mobility | Benchtop |
| Spectral Bandwidth | 2 nm |
| Brand | Lasany |
| Model No / Item Code | Model : LI-294/296 |
| Lamp Type | Deuterium Lamp, Tungsten Lamp |
Features:
▪ Unique optical system, 1200 lines/mm grating and imported receiver to ensure its sound performance.
▪ The instruments is supply with PC software expands the capabilities of the instrument includes
▪ Photo-metric analysis, Quantitative analysis, Spectral scanning, Kinetics, DNA/protein analysis, Multi-wavelength test, etc.
▪ Adopts 51 microcomputer system and store 200 test data and 100 standard curves.
▪ Plug type deuterium lamp and tungsten lamp transfer lamps without optics debugging.
Specifications:
|
Optical System |
Single Beam, Grating 1200 lines/mm |
|
Wavelength Range |
190~1100nm |
|
Spectral Bandwidth |
2 nm |
|
Wavelength Accuracy |
1nm |
|
Wavelength Repeatability |
<=0.2 nm |
|
Photo-metric Accuracy |
0.5%T |
|
Photo-metric Repeatability |
0.2%T |
|
Photo-metric Range |
0 - 200%T, - 0.3 - 3A |
|
Stray light |
0.15%T |
|
Stability |
±0.0002A/h @500nm |
|
Baseline Flatness |
±0.002 A |
|
Noise |
±0.001 A |
|
Wavelength Setting |
Auto |
|
Light Source |
Imported Deuterium & Tungsten lamp |
|
Display |
128*64 LCD |
|
Detector |
Imported Silicon Photodiode |
|
Output |
USB port & Parallel port (Printer) |
|
Power |
AC 220V/50Hz; AC 110V/60Hz |
|
Dimension |
590*460*220mm |
|
Net Weight |
16kg |
|
Shipping Size |
700*580*340mm |
|
Weight |
20kg |
View Complete details