Call 07942672348 98% Response Rate

Send Enquiry

our range

Atomic Absorption Spectrophotometer

Atomic absorption spectrometry [AAS] is an easy, high-throughput, and inexpensive technology used primarily to analyze elements in solution. As such, AAS is used in food and beverage, water, clinical research, and pharmaceutical analysis.

Atomic Absorption Spectrophotometer : Model 272

  • Atomic Absorption Spectrophotometer : Model 272
  • Atomic Absorption Spectrophotometer : Model 272
  • Atomic Absorption Spectrophotometer : Model 272
  • Atomic Absorption Spectrophotometer : Model 272
  • Atomic Absorption Spectrophotometer : Model 272
  • Atomic Absorption Spectrophotometer : Model 272
Atomic Absorption Spectrophotometer : Model 272
Get Best Quote
Rs 7,60,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Product Brochure

Wavelength Range185-900 nm
Optical SystemDouble Beam
MobilityBenchtop
Number Of Lamps4 Lamps
Element DetectionMetals
Spectral BandwidthAuto Positioning, (0.1 to 2.5 nm )
Automation LevelFully Automatic
BrandSystronics India
NebulizerHigh-efficiency Glass Sprayer with Metal sleeve., Corrosion-resistant
Model No / Item CodeType : AAS-272
Country of OriginMade in India

Specifications:

Mode of operation

Both Standalone and PC -Control

Wavelength Range

185-900 nm-(Automatic Positioning)

Display (optional)

In-built Display / LCD Touchscreen (1200x 800 Resolution)-

Multi-touch / Size- 10.1 Inch

Grating

1800 lines/ mm Holographic Grating With Czerny-turner Mechanism

Bandwidth

Auto Positioning, (0.1 to 2.5 nm )

Wavelength Accuracy

±0.2 nm

Wavelength Repeatability

±0.1 nm

Baseline Drift

0.004A/10 min

Source Lamp (HCL)

Four-position, Auto-Position-Turret

Eight-position, Auto-Position-Turret (Optional)

Burner Head

100 mm Single Slit Air-cooled Titanium Metal Burner

Optics

 

Double Beam optics

Detector

PMT ( Photomultiplier tube)

Burner head Adjustment

inbuilt Accurate X-Y Positioner.

Auto positioning with the help of a keyboard (Automatic –optional)

Atomization chamber

Teflon chamber, Corrosion-Resistant

Nebuliser

High-efficiency Glass Sprayer with Metal sleeve., Corrosion-resistant

Flame ignition

Automatic

Mode of measurement

Air-Acetylene Flame Method

Measuring type

 

Concentration, Absorbance (Abs) & Emission

Administrator and User Login

Yes (UP to 5 users )

Operating System

Window 10 64-bit or higher

Audit Trial

Yes

Characteristic

concentration (CC)

0.025µg/ml for Cu

Background correction

Deuterium Lamp method

Printer

Memory

Any Printer supporting windows 10

Inbuilt 128 GB (expandable)

 



View Complete details

Yes! I am Interested Request a call back

AAS - Atomic Absorption Spectrophotometer : Model 271

  • AAS - Atomic Absorption Spectrophotometer : Model 271
  • AAS - Atomic Absorption Spectrophotometer : Model 271
  • AAS - Atomic Absorption Spectrophotometer : Model 271
  • AAS - Atomic Absorption Spectrophotometer : Model 271
  • AAS - Atomic Absorption Spectrophotometer : Model 271
  • AAS - Atomic Absorption Spectrophotometer : Model 271
AAS - Atomic Absorption Spectrophotometer : Model 271
Get Best Quote
Rs 6,60,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Product Brochure

Atomizer TypeFlame
Wavelength Range190-900 nm
Optical SystemSingle Beam
MobilityBenchtop
Number Of Lamps4 Lamps
Element DetectionMetals
Burner100 mm Single Slit Air-cooled Titanium Metal Burner
BrandSystronics India
NebulizerHigh-efficiency Glass Sprayer with Metal sleeve., Corrosion-resistant
Model No / Item CodeType AAS 271
Country of OriginMade in India

Features:

▪ Auto flame ignition [Through PC software]

▪ Auto HCL lamp positioning

▪ Variable bandwidth

▪ High speed of operation

▪ Gas leak sensor

▪ Flame monitor sensor

▪ Auto-gas cut-off

▪ PC Controlled Software

 

Specifications:

Mode of operation

PC Operated Instrument

Wavelength Range

190-900 nm

Grating

1800 lines/ mm Holographic Grating With Czerny-turner

Mechanism

Bandwidth

0.2nm, 0.4 nm, 0.6 nm & 1.2 nm, Auto Positioning

Wavelength Accuracy

±0.2 nm

Wavelength Repeatability

±0.1 nm

Baseline Drift

0.004A/10 min

Source Lamp [HCL]

Four-position, Auto-Position Turret

Burner Head

100 mm Single Slit Air-cooled

Titanium Metal Burner

Burner head Adjustment

Manual With help of an inbuilt Accurate X-Y Positioner

Atomization chamber

Teflon chamber, Corrosion Resistant

Nebuliser

High-efficiency Glass Sprayer with Metal sleeve., Corrosion-resistant

Flame ignition

Automatic

Mode of measurement

Air-Acetylene Flame Method

Measuring type

Concentration and Absorbance [Abs]

Administrator and

User Login

Yes [UP to 5 users ]

Operating System

Window 10 64-bit or higher

Audit Trial

 Yes

Characteristic

concentration [CC]

 

0.025µg/ml for Cu

 

Essential Accessories:

  • Acetylene Gas Cylinder with Regulator
  • Fume Hood
  • Extra HCL Lamp
  • Computer [can be arranged by yourselves at your cost]

 

View Complete details

Yes! I am Interested Request a call back

AAS - Atomic Absorption Spectrophotometer : LI-5310

  • AAS - Atomic Absorption Spectrophotometer : LI-5310
  • AAS - Atomic Absorption Spectrophotometer : LI-5310
  • AAS - Atomic Absorption Spectrophotometer : LI-5310
  • AAS - Atomic Absorption Spectrophotometer : LI-5310
  • AAS - Atomic Absorption Spectrophotometer : LI-5310
  • AAS - Atomic Absorption Spectrophotometer : LI-5310
AAS - Atomic Absorption Spectrophotometer : LI-5310
Get Best Quote
Rs 6,70,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Product Brochure

Wavelength Range190-900 nm
Optical SystemSingle Beam
MobilityBenchtop
Number Of Lamps4 Lamps
Element DetectionMetals
Automation LevelFully Automatic
BurnerAir cooled Titanium
BrandLI
NebulizerHigh-efficient Nebulizer
Model No / Item CodeLI-5310
Features:
  • Advance technology for intelligent stray light measure and correction
  • Original Optical Noise Reduction & Automatic measurement and stray light dynamic detected without any reference materials and incremental cost. It improves instrument’s optical performance, optical  precision, linear range and background correction effectively
  • Develop internal lamp control technology. It makes normal hallow cathode lamps self-absorption background correction possible without and influence to instrument's stability. Meanwhile it will prolong working life of the lamps. Normal hallow cathode lamps are highly economical than special lamps
  • Original ''Hg lamp-regent'' gradient measurement. we established an exact mathematical model to estimate “single beam linear and balance "specification. This technology provided a fast and
  • Economic method for instrument self testing system. It also established a brand new method to improve instrument's detection Performance.
  • Numerous technological innovation and renewal such as design aesthetics, element lamp multi dimensional automatic adjustment system, gas path electronics functional and modular design, No-adjustment D-lamp holder and so on.

Specifications:

Instrument Type

Single Beam Reflection Achromatic Optics System

Monochromator

Aberration Corrected Czerny-Turner

Dispersion elements

Grating system 1200 line/mm characterization area 40mm2

Scintillation wavelength 250nm

Bandwidth

0.1,0.2,0.4,1nm(4 step auto switching)

WL Range

190-900

WL Accuracy

±0.2

WL Repeatability

±0.1 nm max

Resolution

Min 3 lines (279.5 & 279.8 peak and Valley )

HCL housing

Standard 4 lamp turret .

( 1 for measurement , 3 in warm-up mode ) Option :- 6 Lamp / 8 Lamp Turret .

Gas control

Automatic control & optimization (flow/pressure)

Safety measures

Gas Leak check, prevention of gas release when flame dies out,

prevention of flashback through pressure monitoring.

Measurement

Aberration-corrected Czerny-Turner mounting

Photometric Range

0-125%, -0.1-3.00A

Static Baseline Drift

(Cu) +-0.003A/30min

Dynamic Baseline Drift

(Cu) +-0.006A/30min

Background Correction

High speed self-reversal (BGC-SR) method: High

speed D2 lamp method (BGC-D2)

View Complete details

Yes! I am Interested Request a call back

Insize Atomic Absorption Spectrometer Insize

  • Insize Atomic Absorption Spectrometer Insize
  • Insize Atomic Absorption Spectrometer Insize
  • Insize Atomic Absorption Spectrometer Insize
  • Insize Atomic Absorption Spectrometer Insize
Insize Atomic Absorption Spectrometer Insize
Get Best Quote
Rs 9,98,718  / PiecePrice on Request

Product Brochure

Flame TypeGlass
Atomizer TypeGraphite Furnace
Wavelength Range185-900 nm
Number Of Lamps4 Lamps
Element DetectionMetals
Automation LevelFully Automatic
Usage AreaMining Lab, Pharma Lab, Food Lab, Water Lab, Environmental Lab
RepeatabilityRSD≤1%

Lamp Position

4 Positions

Static Baseline Drift [Cu]

±0.004A/30min

Dynamic Baseline Drift [Cu]

±0.006A/15min

Characteristic Concentration [Cu]

≤0.04 µg/ml

Detection Limit [Cu]

≤0.008 µg/ml

Background Calibration

Deuterium Lamp ≥ 30 Times [1Abs]

Repeatability

RSD≤1%

Wavelength Error

0.3nm

Wavelength Repeatability

≤0.1nm

Wavelength Range

185~900nm

Display Data

Transmittance, Absorbance, Concentration

Photometric Range

0~125%, -0.1~3.00A

Beam Type

Single Beam

Monochromator

C-T Type, Focal Length 350mm

Dispersive Element

Raster Scribing 1800 Lines/Mm, Scintillation Wavelength

Spectral Bandwidth

Six Levels Auto-Matic Switching [0.1, 0.2, 0.4, 0.7, 1.4, 2nm]

Spectral Bandwidth Deviation

±0.02nm

Natural Gas

C₂H₂ [≥99.9%]

C₂H₂ Flow Adjustment

Automatic 12 Levels

Air Flow Adjustment

Automatic 4 Levels

Burner

Titanium Metal Burner [Auto-Matic Lifting And Lowering]

Atomizer

Glass Atomizer

Atomization Chamber

Corrosion Resistant Atomization Chamber

Safety Measure

Gas Pressure Protection

Measurement Method

Flame Method, Hydride Generation-Atomic Absorption, Flame Emission

Concentration Calculation

Standard Curve Method, Standard Addition Method, Interpolation Method

 


View Complete details

Yes! I am Interested Request a call back

Atomic Absorption Spectrophotometer With 4 Lamps - AAS4M

  • Atomic Absorption Spectrophotometer With 4 Lamps - AAS4M
  • Atomic Absorption Spectrophotometer With 4 Lamps - AAS4M
  • Atomic Absorption Spectrophotometer With 4 Lamps - AAS4M
  • Atomic Absorption Spectrophotometer With 4 Lamps - AAS4M
Atomic Absorption Spectrophotometer With 4 Lamps - AAS4M
Get Best Quote
Rs 5,70,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Product Brochure

Flame TypeAir Acetylene
Atomizer TypeFlame
Wavelength Range190-900 nm
Number Of Lamps4 Lamps
Element DetectionMetals
Automation LevelManual
Operation SettingManual
Lamp Socket Options4 Lamps
Scintillation Wavelength250nm
Grating System1800 line/mm Characterization Area of 40mm2
Wavelength Repeatability±0.1 nm
Wavelength Accuracy±0.2 nm
Optical SystemCzerny - Turner System, Integrated Optical Bench, Closed Optical System
ResolutionSpectral Bandwidth 0.2nm can separate Min Double Line [279.5/279.8] & Peak Valley
Instrument TypeSingle Beam Reflection Achromatic Optics System
Spectrum Slit6-Gear Automatic Switching [0.1, 0.2, 0.4, 0.7,1.0, 2.0nm]
Photometric Range0-125%, -0.1-3.00A
Static Baseline Drift≤ 0.002ABS/30min[Cu]
Background Correction MethodHigh Speed Self-reversal [BGC-SR], High Speed D2 lamp[BGC-D2]
Combustion HeadAir-Acetylene flame Combusion Head 100mm
SprayerHigh Efficiency Glass Sprayer
Dynamic Drift of IgnitionBaseline ≤ 0.004ABS/30min [Cu]
Characteristic Concentration of Cu0.025ug/ml/1% [Cu, ABS>0.8ABS]
Detection LimitCu ≤ 0.008ug/ml
Measurement Repeatability [Cu]RSD < 0.5%
Ambient Temperature10 to 30°C
Standard LampCu
Features:
▪AAS4M - Flame, Fuel Gas C2H2 [Acetylene + Air]
▪Hollow Cathode Lamps - Copper - Cu Standard supply, other lamps optional available 
▪Standard Software supplied with instrument▪Computer not available with instrument. User must have the Computer to connect the software

Hollow Cathode Lamps :Cu - Copper | Zn - Zinc | Fe - Iron | Mn - Manganese | Pb - Lead | Mg - Magnesium | Ni - Nickel | Cd- Cadmium | Ca - CalciumCr - Chromium  | Li - Lithium | Co - Cobalt

View Complete details

Yes! I am Interested Request a call back

Atomic Absorption Spectrophotometer With 8 Lamps - AAS8A

  • Atomic Absorption Spectrophotometer With 8 Lamps - AAS8A
  • Atomic Absorption Spectrophotometer With 8 Lamps - AAS8A
  • Atomic Absorption Spectrophotometer With 8 Lamps - AAS8A
  • Atomic Absorption Spectrophotometer With 8 Lamps - AAS8A
Atomic Absorption Spectrophotometer With 8 Lamps - AAS8A
Get Best Quote
Rs 6,40,000  / PiecePrice on Request

Product Brochure

Atomizer TypeFlame And Furnace
Number Of Lamps8 Lamps
Element DetectionMetals
Automation LevelFully Automatic
Usage AreaFood Lab, Water Lab, Environmental Lab, Pharma Lab

Features:

▪ AAS8A - Flame & Graphite Furnace Auto sampler and RCB can be attached [Optional]

▪ For Graphite Argon[Ar] gas required

▪ Gas control Automatic Control and Optimization 

Specifications:

Operation Setting

Automatic

Lamp Socket Options

8 Lamps

Make

LABMAN

Wavelength Range

190 – 900 nm

Scintillation Wavelength

250nm

Grating System

1800 line/mm Characterization Area of 40mm2

Wavelength Repeatability

±0.1 nm

Wavelength Accuracy

±0.2 nm

Optical System

Czerny - Turner System, Integrated Optical Bench, Closed Optical System

Resolution

Spectral Bandwidth 0.2nm can separate Min Double Line [279.5/279.8] & Peak Valley

Instrument Type

Single Beam Reflection Achromatic Optics System

Spectrum Slit

6-Gear Automatic Switching [0.1, 0.2, 0.4, 0.7,1.0, 2.0nm]

Photometric Range

0-125%, -0.1-3.00A

Static Baseline Drift

≤ 0.002ABS/30min[Cu]

Background Correction Method

High Speed Self-reversal [BGC-SR], High Speed D2 lamp[BGC-D2]

Combustion Head

Air-Acetylene flame Combusion Head 100mm

Sprayer

High Efficiency Glass Sprayer

Dynamic Drift of Ignition

Baseline ≤ 0.004ABS/30min [Cu]

Characteristic Concentration of Cu

0.025ug/ml/1% [Cu, ABS>0.8ABS]

Detection Limit

Cu ≤ 0.004ug/ml

Measurement Repeatability [Cu]

RSD < 0.5%

Ambient Temperature

10 to 30°C

Standard Lamp

Cu

Software

Available

Power Supply

AC 220V /50-60Hz 

View Complete details