Vasai, Palghar, Maharashtra
GST No. 27AEZFS6417A1ZO
Call 07942672348 98% Response Rate
Send Enquiry
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 185-900 nm |
| Optical System | Double Beam |
| Mobility | Benchtop |
| Number Of Lamps | 4 Lamps |
| Element Detection | Metals |
| Spectral Bandwidth | Auto Positioning, (0.1 to 2.5 nm ) |
| Automation Level | Fully Automatic |
| Brand | Systronics India |
| Nebulizer | High-efficiency Glass Sprayer with Metal sleeve., Corrosion-resistant |
| Model No / Item Code | Type : AAS-272 |
| Country of Origin | Made in India |
Specifications:
|
Mode of operation |
Both Standalone and PC -Control |
|
Wavelength Range |
185-900 nm-(Automatic Positioning) |
|
Display (optional) |
In-built Display / LCD Touchscreen (1200x 800 Resolution)- Multi-touch / Size- 10.1 Inch |
|
Grating |
1800 lines/ mm Holographic Grating With Czerny-turner Mechanism |
|
Bandwidth |
Auto Positioning, (0.1 to 2.5 nm ) |
|
Wavelength Accuracy |
±0.2 nm |
|
Wavelength Repeatability |
±0.1 nm |
|
Baseline Drift |
0.004A/10 min |
|
Source Lamp (HCL) |
Four-position, Auto-Position-Turret Eight-position, Auto-Position-Turret (Optional) |
|
Burner Head |
100 mm Single Slit Air-cooled Titanium Metal Burner |
|
Optics
|
Double Beam optics |
|
Detector |
PMT ( Photomultiplier tube) |
|
Burner head Adjustment |
inbuilt Accurate X-Y Positioner. Auto positioning with the help of a keyboard (Automatic –optional) |
|
Atomization chamber |
Teflon chamber, Corrosion-Resistant |
|
Nebuliser |
High-efficiency Glass Sprayer with Metal sleeve., Corrosion-resistant |
|
Flame ignition |
Automatic |
|
Mode of measurement |
Air-Acetylene Flame Method |
|
Measuring type
|
Concentration, Absorbance (Abs) & Emission |
|
Administrator and User Login |
Yes (UP to 5 users ) |
|
Operating System |
Window 10 64-bit or higher |
|
Audit Trial |
Yes |
|
Characteristic concentration (CC) |
0.025µg/ml for Cu |
|
Background correction |
Deuterium Lamp method |
|
Printer Memory |
Any Printer supporting windows 10 Inbuilt 128 GB (expandable) |
|
|
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Atomizer Type | Flame |
| Wavelength Range | 190-900 nm |
| Optical System | Single Beam |
| Mobility | Benchtop |
| Number Of Lamps | 4 Lamps |
| Element Detection | Metals |
| Burner | 100 mm Single Slit Air-cooled Titanium Metal Burner |
| Brand | Systronics India |
| Nebulizer | High-efficiency Glass Sprayer with Metal sleeve., Corrosion-resistant |
| Model No / Item Code | Type AAS 271 |
| Country of Origin | Made in India |
Features:
▪ Auto flame ignition [Through PC software]
▪ Auto HCL lamp positioning
▪ Variable bandwidth
▪ High speed of operation
▪ Gas leak sensor
▪ Flame monitor sensor
▪ Auto-gas cut-off
▪ PC Controlled Software
Specifications:
|
Mode of operation |
PC Operated Instrument |
|
Wavelength Range |
190-900 nm |
|
Grating |
1800 lines/ mm Holographic Grating With Czerny-turner Mechanism |
|
Bandwidth |
0.2nm, 0.4 nm, 0.6 nm & 1.2 nm, Auto Positioning |
|
Wavelength Accuracy |
±0.2 nm |
|
Wavelength Repeatability |
±0.1 nm |
|
Baseline Drift |
0.004A/10 min |
|
Source Lamp [HCL] |
Four-position, Auto-Position Turret |
|
Burner Head |
100 mm Single Slit Air-cooled Titanium Metal Burner |
|
Burner head Adjustment |
Manual With help of an inbuilt Accurate X-Y Positioner |
|
Atomization chamber |
Teflon chamber, Corrosion Resistant |
|
Nebuliser |
High-efficiency Glass Sprayer with Metal sleeve., Corrosion-resistant |
|
Flame ignition |
Automatic |
|
Mode of measurement |
Air-Acetylene Flame Method |
|
Measuring type |
Concentration and Absorbance [Abs] |
|
Administrator and User Login |
Yes [UP to 5 users ] |
|
Operating System |
Window 10 64-bit or higher |
|
Audit Trial |
Yes |
|
Characteristic concentration [CC]
|
0.025µg/ml for Cu |
Essential Accessories:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Wavelength Range | 190-900 nm |
| Optical System | Single Beam |
| Mobility | Benchtop |
| Number Of Lamps | 4 Lamps |
| Element Detection | Metals |
| Automation Level | Fully Automatic |
| Burner | Air cooled Titanium |
| Brand | LI |
| Nebulizer | High-efficient Nebulizer |
| Model No / Item Code | LI-5310 |
|
Instrument Type |
Single Beam Reflection Achromatic Optics System |
|
Monochromator |
Aberration Corrected Czerny-Turner |
|
Dispersion elements |
Grating system 1200 line/mm characterization area 40mm2 Scintillation wavelength 250nm |
|
Bandwidth |
0.1,0.2,0.4,1nm(4 step auto switching) |
|
WL Range |
190-900 |
|
WL Accuracy |
±0.2 |
|
WL Repeatability |
±0.1 nm max |
|
Resolution |
Min 3 lines (279.5 & 279.8 peak and Valley ) |
|
HCL housing |
Standard 4 lamp turret . ( 1 for measurement , 3 in warm-up mode ) Option :- 6 Lamp / 8 Lamp Turret . |
|
Gas control |
Automatic control & optimization (flow/pressure) |
|
Safety measures |
Gas Leak check, prevention of gas release when flame dies out, prevention of flashback through pressure monitoring. |
|
Measurement |
Aberration-corrected Czerny-Turner mounting |
|
Photometric Range |
0-125%, -0.1-3.00A |
|
Static Baseline Drift |
(Cu) +-0.003A/30min |
|
Dynamic Baseline Drift |
(Cu) +-0.006A/30min |
|
Background Correction |
High speed self-reversal (BGC-SR) method: High speed D2 lamp method (BGC-D2) |
View Complete details
Product Brochure
| Flame Type | Glass |
| Atomizer Type | Graphite Furnace |
| Wavelength Range | 185-900 nm |
| Number Of Lamps | 4 Lamps |
| Element Detection | Metals |
| Automation Level | Fully Automatic |
| Usage Area | Mining Lab, Pharma Lab, Food Lab, Water Lab, Environmental Lab |
| Repeatability | RSD≤1% |
|
Lamp Position |
4 Positions |
|
Static Baseline Drift [Cu] |
±0.004A/30min |
|
Dynamic Baseline Drift [Cu] |
±0.006A/15min |
|
Characteristic Concentration [Cu] |
≤0.04 µg/ml |
|
Detection Limit [Cu] |
≤0.008 µg/ml |
|
Background Calibration |
Deuterium Lamp ≥ 30 Times [1Abs] |
|
Repeatability |
RSD≤1% |
|
Wavelength Error |
0.3nm |
|
Wavelength Repeatability |
≤0.1nm |
|
Wavelength Range |
185~900nm |
|
Display Data |
Transmittance, Absorbance, Concentration |
|
Photometric Range |
0~125%, -0.1~3.00A |
|
Beam Type |
Single Beam |
|
Monochromator |
C-T Type, Focal Length 350mm |
|
Dispersive Element |
Raster Scribing 1800 Lines/Mm, Scintillation Wavelength |
|
Spectral Bandwidth |
Six Levels Auto-Matic Switching [0.1, 0.2, 0.4, 0.7, 1.4, 2nm] |
|
Spectral Bandwidth Deviation |
±0.02nm |
|
Natural Gas |
C₂H₂ [≥99.9%] |
|
C₂H₂ Flow Adjustment |
Automatic 12 Levels |
|
Air Flow Adjustment |
Automatic 4 Levels |
|
Burner |
Titanium Metal Burner [Auto-Matic Lifting And Lowering] |
|
Atomizer |
Glass Atomizer |
|
Atomization Chamber |
Corrosion Resistant Atomization Chamber |
|
Safety Measure |
Gas Pressure Protection |
|
Measurement Method |
Flame Method, Hydride Generation-Atomic Absorption, Flame Emission |
|
Concentration Calculation |
Standard Curve Method, Standard Addition Method, Interpolation Method |
|
|
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
| Flame Type | Air Acetylene |
| Atomizer Type | Flame |
| Wavelength Range | 190-900 nm |
| Number Of Lamps | 4 Lamps |
| Element Detection | Metals |
| Automation Level | Manual |
| Operation Setting | Manual |
| Lamp Socket Options | 4 Lamps |
| Scintillation Wavelength | 250nm |
| Grating System | 1800 line/mm Characterization Area of 40mm2 |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Accuracy | ±0.2 nm |
| Optical System | Czerny - Turner System, Integrated Optical Bench, Closed Optical System |
| Resolution | Spectral Bandwidth 0.2nm can separate Min Double Line [279.5/279.8] & Peak Valley |
| Instrument Type | Single Beam Reflection Achromatic Optics System |
| Spectrum Slit | 6-Gear Automatic Switching [0.1, 0.2, 0.4, 0.7,1.0, 2.0nm] |
| Photometric Range | 0-125%, -0.1-3.00A |
| Static Baseline Drift | ≤ 0.002ABS/30min[Cu] |
| Background Correction Method | High Speed Self-reversal [BGC-SR], High Speed D2 lamp[BGC-D2] |
| Combustion Head | Air-Acetylene flame Combusion Head 100mm |
| Sprayer | High Efficiency Glass Sprayer |
| Dynamic Drift of Ignition | Baseline ≤ 0.004ABS/30min [Cu] |
| Characteristic Concentration of Cu | 0.025ug/ml/1% [Cu, ABS>0.8ABS] |
| Detection Limit | Cu ≤ 0.008ug/ml |
| Measurement Repeatability [Cu] | RSD < 0.5% |
| Ambient Temperature | 10 to 30°C |
| Standard Lamp | Cu |
View Complete details
Product Brochure
| Atomizer Type | Flame And Furnace |
| Number Of Lamps | 8 Lamps |
| Element Detection | Metals |
| Automation Level | Fully Automatic |
| Usage Area | Food Lab, Water Lab, Environmental Lab, Pharma Lab |
Features:
▪ AAS8A - Flame & Graphite Furnace Auto sampler and RCB can be attached [Optional]
▪ For Graphite Argon[Ar] gas required
▪ Gas control Automatic Control and Optimization
Specifications:
|
Operation Setting |
Automatic |
|
Lamp Socket Options |
8 Lamps |
|
Make |
LABMAN |
|
Wavelength Range |
190 – 900 nm |
|
Scintillation Wavelength |
250nm |
|
Grating System |
1800 line/mm Characterization Area of 40mm2 |
|
Wavelength Repeatability |
±0.1 nm |
|
Wavelength Accuracy |
±0.2 nm |
|
Optical System |
Czerny - Turner System, Integrated Optical Bench, Closed Optical System |
|
Resolution |
Spectral Bandwidth 0.2nm can separate Min Double Line [279.5/279.8] & Peak Valley |
|
Instrument Type |
Single Beam Reflection Achromatic Optics System |
|
Spectrum Slit |
6-Gear Automatic Switching [0.1, 0.2, 0.4, 0.7,1.0, 2.0nm] |
|
Photometric Range |
0-125%, -0.1-3.00A |
|
Static Baseline Drift |
≤ 0.002ABS/30min[Cu] |
|
Background Correction Method |
High Speed Self-reversal [BGC-SR], High Speed D2 lamp[BGC-D2] |
|
Combustion Head |
Air-Acetylene flame Combusion Head 100mm |
|
Sprayer |
High Efficiency Glass Sprayer |
|
Dynamic Drift of Ignition |
Baseline ≤ 0.004ABS/30min [Cu] |
|
Characteristic Concentration of Cu |
0.025ug/ml/1% [Cu, ABS>0.8ABS] |
|
Detection Limit |
Cu ≤ 0.004ug/ml |
|
Measurement Repeatability [Cu] |
RSD < 0.5% |
|
Ambient Temperature |
10 to 30°C |
|
Standard Lamp |
Cu |
|
Software |
Available |
|
Power Supply |
AC 220V /50-60Hz |
View Complete details