Call 08044564523 97% Response Rate
Send Enquiry
Product Brochure
Wavelength Range | 340-960 nm |
Optical System | Single Beam |
Spectral Bandwidth | 5 nm |
Mobility | Benchtop |
Brand | Systronics |
Model No / Item Code | type 106 |
Wavelength Accuracy | +-5.0 nm |
Wavelength Repeatability | 5 nm |
Lamp Type | Tungsten Halogen Lamp |
Country of Origin | Made in India |
µ Controller Based Visible Spectrophotometer - Type 106
Make : Systronics
Model : Type 106
Features:
▪ Micro-controller based
▪ %T, Abs, Conc. & K factor measuring modes
▪ Single Position 20/50 mm Cuvette Holder [Optional]
Wavelength Range |
340-960 nm |
Optical System |
Double Beam |
Spectral Bandwidth |
5 nm |
Mobility |
Benchtop |
Application |
Laboratory Use |
Brand |
Systronics |
Model No / Item Code |
106 |
Wavelength Accuracy |
+-5.0 nm |
Wavelength Repeatability |
5 nm |
Photometric Accuracy |
+-0.005 Abs |
Photometric Range |
-0.3- 2.5 A, 0-9999 C |
Photometric Repeatability |
0.1 % T |
Detector |
Silicon Photodiode |
Lamp Type |
Tungsten Halogen Lamp |
Grating |
600 line / mm |
Dimensions |
420 * 310 * 125 mm |
Material |
Fiber / Plastic |
Power |
230 V +_ 10%, AC 50 Hz |
Voltage |
230 V |
Frequency |
50 Hz |
Weight |
6.5kg |
Country of Origin |
Made in India |
Display |
4 Digit LED |
Wavelength Range |
340-960 nm |
Optical System |
Double Beam |
Spectral Bandwidth |
5 nm |
Mobility |
Benchtop |
Application |
Laboratory Use |
View Complete details
Product Brochure
Wavelength Range | 340-990 nm |
Optical System | Single Beam |
Spectral Bandwidth | 5 nm |
Mobility | Benchtop |
Brand | Spectrophotometer |
Model No / Item Code | Type 166 |
Wavelength Accuracy | +-2.0 nm |
Wavelength Repeatability | 1 nm |
Photometric Accuracy | +- 0.1% T |
Lamp Type | Tungsten Halogen Lamp |
Country of Origin | Made in India |
µ Controller Based Visible Spectrophotometer - Type 166
Make : Systronics
Model : Type 166
Features:
▪ Micro-controller based
▪ Digital Wavelength
▪ Photometric Readout - 4 Digit LED
▪ %T, Abs, Conc. & K factor measuring modes
▪ Single Position 20/50 mm Cuvette Holder [Optional]
SPECIFICATIONS
Wavelength Range |
340-990 nm |
Spectral Bandwidth |
5 nm |
Application |
Laboratory Use |
Brand |
Systronics |
Model No / Item Code |
166 |
Machine Type |
Benchtop |
Wavelength Accuracy |
+-2.0 nm |
Wavelength Repeatability |
1 nm |
Photometric Accuracy |
+-0.005 Abs |
Photometric Range |
-0.3- 2.5 A, 0-9999 C |
Photometric Repeatability |
0.1 % T |
Detector |
Silicon Photodiode |
Lamp Type |
Tungsten Halogen Lamp |
Dimensions |
420 * 310 * 125 mm |
Grating |
600 line / mm |
Voltage |
230 V |
Frequency |
50 Hz |
Weight |
6.5kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Wavelength Range | 340-999 nm |
Optical System | Single Beam |
Mobility | Benchtop |
Spectral Bandwidth | 5 nm |
Brand | Systronics |
Model No / Item Code | Type 167 |
Wavelength Accuracy | +-2.0 nm |
Wavelength Repeatability | +- 0.2 nm |
Photometric Accuracy | +-0.005 A |
Lamp Type | Tungsten Halogen Lamp |
Country of Origin | Made in India |
Visiscan Spectrophotometer- Type 167
Make : Systronics
Model : Type 167
Features:
▪ Micro-controller based
▪ %T, Abs, Conc. measuring modes
▪ Single Wavelength, Multi Wavelength, Scan Operating modes
▪ 5 nm Bandwidth
▪ 4 Position automatic sample changer [Optional]
▪ Printer interface [Optional]
▪ PC interface [Optional]
Specifications:
Wavelength Range |
340-999 nm |
Optical System |
Single Beam |
Mobility |
Benchtop |
Spectral Bandwidth |
5 nm |
Application |
Laboratory Use |
Brand |
Systronics |
Model No / Item Code |
167-VISISCAN |
Wavelength Accuracy |
+-2.0 nm |
Wavelength Repeatability |
+- 0.2 nm |
Photometric Accuracy |
+-0.005 A |
Photometric Range |
-0.04 to 2.5 Abs ; 0.1 to 9999 C |
Photometric Repeatability |
+-0.005 A |
Stray Light |
Less than equal to 0.3%T. |
Stability |
+- 0.001 A/h. |
Detector |
Silicon Photodiode |
Lamp Type |
Tungsten Halogen Lamp |
Grating |
600 Lines/nm |
Baseline Flatness |
+- 0.005 Abs |
Display |
2 Line 20 Characters LCD |
Dimensions |
420 * 310 * 125 mm |
Material |
Fiber / Plastic |
Power |
230 V +_ 10%, AC 50 Hz |
Voltage |
230 V |
Frequency |
50 Hz |
Weight |
6.5kg |
View Complete details
Product Brochure
Wavelength Range | 340 -1100 nm |
Optical System | Single Beam |
Mobility | Benchtop |
Spectral Bandwidth | 2 nm |
Brand | systronics |
Model No / Item Code | Type 168 |
Wavelength Accuracy | +-1.0 nm |
Wavelength Repeatability | +-.5 nm |
µ Controller Based Visible Spectrophotometer with Graphic LCD Display - Type 168
Make : Systronics
Model : Type 168
Features:
▪ Micro-controller based
▪ %T, Abs, Conc. [K factor, Multi standard] measuring modes
▪ Single Wavelength, Multi Wavelength, Scan, Time Scan, Online measurement facility
▪ Data stored for each operating modes
▪ Single Position 50 mm Cuvette Holder [Optional]
▪ Printer interface [Optional]
▪ PC interface [Optional]
Specifications:
Wavelength Range | 340 -1100 nm |
Optical System | Single Beam |
Spectral Bandwidth | 2 nm |
Application | Laboratory Use |
Brand | Systronics |
Model No / Item Code | 168 |
Wavelength Accuracy | +-1.0 nm |
Wavelength Repeatability | +-0.5 nm |
Photometric Accuracy | +-0.005 Abs |
Photometric Range | -0.04 to 3.0 Abs |
Photometric Repeatability | +-0.002 Abs |
Stray Light | Less than equal to 0.1%T |
Detector | Silicon Photodiode |
Lamp Type | Tungsten Halogen Lamp |
Grating | 1200 lines / mm |
Baseline Flatness | +- 0.005 Abs |
Dimensions | 480*410*215 mm |
Voltage | 230 V |
Frequency | 50 Hz |
Weight | 13 kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Wavelength Range | 325-1100 nm |
Optical System | Single Beam |
Spectral Bandwidth | 4 nm |
Mobility | Benchtop |
Brand | Si |
Model No / Item Code | Si-200 |
Wavelength Accuracy | +-2.0 nm |
Wavelength Repeatability | +-1 nm |
Photometric Accuracy | +-0.5% T |
Lamp Type | Tungsten Lamp |
PRODUCT NAME |
VISIBLE SPECTROPHOTOMETER |
MODEL |
Si-200 |
Wavelength Range |
320-1100nm |
Spectral Bandwidth |
4nm |
Light Source |
Tungsten lamp |
Optical System |
Single Beam, Grating 1200 lines/mm |
Wavelength Accuracy |
+ 2 nm |
Wavelength Repeatability |
+ 1nm |
Photometric Accuracy |
+ 0.5%T |
Photometric Repeatability |
+ 0.2%T |
Photometric Mode |
T, A, C |
Stray light & Stability |
0.15%T @500nm & 0.002 A@500nm |
Wavelength Setting |
Manual |
Display |
70 x 40mm blue-lit LCD |
Detector & Cell Holder |
Silicon Photodiode & 4 position 10mm cell holder |
Output |
RS232C |
Power supply |
AC220V/50Hz |
Packing Dimension (LxWxH) |
520 x 450 x 320mm |
Gross Weight |
10kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Wavelength Range | 330 to 1020nm |
Optical System | Single Beam |
Mobility | Benchtop |
Spectral Bandwidth | 5nm |
Brand | Spectrasonic |
Model No / Item Code | Si-100 |
Wavelength Accuracy | +-2nm |
Country of Origin | Made in India |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Wavelength Range | 320-1000 nm |
Optical System | Single Beam |
Spectral Bandwidth | 2 nm |
Mobility | Benchtop |
Brand | Lasany |
Model No / Item Code | LI-721 S |
Lamp Type | Tungsten Halogen Lamp |
Wavelength Range |
320-1000nm |
Light Source Lamp |
Tungsten Halogen Lamp 20W/12V |
Wavelength Accuracy |
±2 nm |
Wavelength Reproducibility |
1 nm |
Band Width |
2 nm |
Photo-metric Accuracy |
±0.5%[T] |
Photo-metric Reproducibility |
0.2%[T] |
Stray Light |
±0.2%[T] |
Noise |
±0.2%[T] |
Size [L*W*H] Main Unit |
370*320*190mm |
Power Requirement |
220V/110V±10% 50/60 Hz |
Interface |
RS232 serial & parallel interface |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Wavelength Range | 325-1000nm |
Optical System | Single Beam |
Spectral Bandwidth | 4 nm |
Mobility | Portable |
Brand | Lasany |
Model No / Item Code | LI-730 |
Lamp Type | Tungsten Lamp |
Features:
▪ Can display wavelength, absorption and transmittance with 5 results per screen. It also has a memory store of up to 200 results.
▪ 8mm Optical Base - The instruments use a rigid die-cast aluminum base as its optical mount to ensure instrument stability and reliability
▪ Users set wavelength automatically through arrow keys to avoid operation errors
▪ Can set up various standard curves according to customers solutions and find the concentration of unknown solutions
▪ Equipped with USB port to connect with a PC to display spectrum scanning, kinetics and multi wavelength testing results on the screen.
▪ Equipped with a 2.5 LCD screen to give a clear display of standard curves and groups of results.
Specifications:
Optical System |
Single beam, Grating 1200 lines/mm |
Wavelength Range |
325-1000nm |
Bandwidth |
4nm |
Wavelength Accuracy |
1nm |
Wavelength Repeatability |
0.5nm |
Wavelength Setting |
Auto |
Photo-metric Accuracy |
0.5%T |
Photo-metric Repeatability |
0.3%T |
Photo-metric Range |
-0.3-3A,0-200%T |
Stray Light |
0.3%T |
Stability |
0.002A/h @ 500nm |
Display |
LCD |
Detector |
Silicon Photo diode |
Standard Cell Holder |
4-position 10mm cell holder |
Light Source |
Tungsten Lamp |
Output |
USB Port & Parallel Port[Printer] |
Power Supply |
AC 220V/50Hz |
Dimension [LxWxH] mm |
420x280x180 |
Weight |
10kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Wavelength Range | 325-1000 nm |
Optical System | Single Beam |
Spectral Bandwidth | 2 nm |
Mobility | Benchtop |
Brand | Lasany |
Model No / Item Code | LI-722 |
Lamp Type | Tungsten Lamp |
Features:
▪ The monochromator with a holographic flashing grating is used. It has the advantage of high wavelength precision, good monochromaticity
▪ A sample compartment for 0.5cm-10cm cells,
▪ Computer control system, precise automatic T/A changeover,
▪ Automatic zero and full scale adjustment.
▪ Direct concentration read-out and concentration factor setting function.
▪ Equipped with R$232 port. Data can be sent to PC by special software
Specifications:
Optical System |
Single Beam |
Spectral Bandwidth |
2 nm |
Wavelength Range |
325-1000 nm |
Model Name/Number |
Microprocessor Single Beam Visible Spectrophotometer With Software |
Wavelength Accuracy |
Less than 2 nm |
Wavelength Repeatability |
Less than 1 nm |
Stray Light |
Less than 0.5 % [at 360 nm, NaNO] |
Dark current drift |
0.2 %/3 min |
Cell holder |
10 mm |
Light current drift |
0.5 %/3 min |
Dimensions |
56 x 48 x 29 cms |
Net weight |
11.5 kgs |
Transmittance accuracy |
+/-0.5 % |
Gross weight |
13.5 kgs |
Transmittance repeatability |
Less than 0.2 % |
Spectrum bandwidth |
2 nm/1 nm |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Wavelength Range | 320-1020nm |
Optical System | Single Beam |
Mobility | Benchtop |
Spectral Bandwidth | 2 nm |
Brand | Lasany |
Model No / Item Code | LI-721 |
Lamp Type | Tungsten Lamp |
Features:
▪ The Monochromator with a holographic flashing grating is used.
▪ It has the advantage of high wavelength precision, good monochromatic and low stray light.
▪ A sample compartment is equipped with 50 mm cell holder
▪ Direct concentration read - out and concentration factor setting function.
▪ Equipped with RS232 Port.
Specifications:
Optical System |
C-T Single Beam, Grating 1200lines/mm |
Wavelength Range |
320-1020nm |
Spectral Bandwidth |
2nm |
Wavelength Interval |
1nm |
Wavelength Accuracy |
±2nm |
Wavelength Repeatability |
<1nm |
Photo-metric Accuracy |
±1%T |
Photo-metric Repeatability |
0.5%T |
Photo-metric Range |
0-1.999A, 0-199.9%T |
Stray Light |
<0.3%T@340nm |
Stability |
±0.004A/h @500nm |
Display |
4 LCD |
Photo-metric Mode |
T,A,C |
Detector |
Si Photodiode |
Light Source |
Tungsten lamp |
Power Requirement |
AC [ 220V/50HZ] |
Dimensions |
[W x D x H] 450 x 520 x 320mm |
Weight |
10 kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Wavelength Range | 320-1020nm |
Optical System | Single Beam |
Mobility | Benchtop |
Spectral Bandwidth | 2 nm |
Brand | Lasany |
Model No / Item Code | LI-721 |
Lamp Type | Tungsten Lamp |
Features:
▪ The Monochromator with a holographic flashing grating is used.
▪ It has the advantage of high wavelength precision, good monochromatic and low stray light.
▪ A sample compartment is equipped with 50 mm cell holder
▪ Direct concentration read - out and concentration factor setting function.
▪ Equipped with RS232 Port.
Specifications:
Optical System |
C-T Single Beam, Grating 1200lines/mm |
Wavelength Range |
320-1020nm |
Spectral Bandwidth |
2nm |
Wavelength Interval |
1nm |
Wavelength Accuracy |
±2nm |
Wavelength Repeatability |
<1nm |
Photo-metric Accuracy |
±1%T |
Photo-metric Repeatability |
0.5%T |
Photo-metric Range |
0-1.999A, 0-199.9%T |
Stray Light |
<0.3%T@340nm |
Stability |
±0.004A/h @500nm |
Display |
4 LCD |
Photo-metric Mode |
T,A,C |
Detector |
Si Photodiode |
Light Source |
Tungsten lamp |
Power Requirement |
AC [ 220V/50HZ] |
Dimensions |
[W x D x H] 450 x 520 x 320mm |
Weight |
10 kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Wavelength Range | 325-1000nm |
Optical System | Single Beam |
Mobility | Benchtop |
Spectral Bandwidth | 4 nm |
Model No / Item Code | LMSP-V320 |
Brand | Labman |
Lamp Type | Tungsten Halogen Lamp |
Usage / Application | LMSPV320 can display absorption, transmittance, concentration and coefficient directly by different |
Warranty | 2 Years Guarantee |
Voltage | AC 220V,50/60Hz |
Wavelength | 325-1000nm |
Type | Vis. Spectrophotometer |
Country of Origin | Made in India |
Model |
LMSPV320 |
Make |
LABMAN |
Optical System |
Single Beam, Grating 1200 lines/mm |
Wavelength Range |
325-1000nm |
Spectral Bandwidth |
4nm |
Wavelength Accuracy |
+2nm |
Wavelength Repeatability |
+1nm |
Wavelength Setting |
Manual |
Photometric Accuracy |
+0.5%T |
Photometric Repeatability |
+0.3%T |
Photometric Range |
-0.3-3A,0-200%T |
Photometric Mode |
T.A.C.F |
Stray Light |
s0.3%T |
Stability |
+ 0.002A/h |
Display |
LCD |
Detector & Light Source |
Silicon Photodiode & Tungsten Halogen Lamp |
Output |
USB Port & Parallel Port(Printer) |
Power Supply |
AC 220V,50/60Hz |
Dimension (LxWxH) mm |
420x280x180mm |
Weight |
8kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Wavelength Range | 325-1000 nm |
Optical System | Single Beam |
Mobility | Benchtop |
Spectral Bandwidth | 4 nm |
Model No / Item Code | LMSP-V325 |
Brand | Labman |
Lamp Type | Tungsten Halogen Lamp |
Usage / Application | Can set up various standard curves according to customer's solutions and find the concentration of u |
Warranty | 2 Year Guarantee |
Voltage | 240 V |
Frequency | 50 Hz |
Wavelength | 325-1000 nm |
Type | Visible Spectrophotometer |
Country of Origin | Made in India |
Model |
LMSPV325 |
Make |
LABMAN |
Optical System |
Single beam, Grating 1200 lines/mm |
Wavelength Range |
325-1000nm |
Bandwidth |
4nm |
Wavelength Accuracy |
±1nm |
Wavelength Repeatability |
±0.5nm |
Wavelength Setting |
Automatic |
Photometric Accuracy |
±0.5%T |
Photometric Repeatability |
±0.3%T |
Photometric Range |
-0.3-3A,0-200%T |
Photometric Mode |
T, A, C, F |
Stray Light |
<0.3%T |
Stability |
± 0.002A/h @ 500nm |
Display |
LCD |
Detector & Light Source |
Silicon Photodiode &Tungsten Lamp |
Standard Cell Holder |
4-position 10mm cell holder |
Output |
USB Port & Parallel Port(Printer) |
Power Supply |
AC 220V,50/60Hz |
Dimension (LxWxH) mm |
420x280x180 |
Weight |
10kg |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Wavelength Range | 340-960 |
Optical System | Single Beam |
Mobility | Benchtop |
Brand | Systronics |
Model No / Item Code | Model 104 |
Wavelength Accuracy | +- 0.5 nm |
µ Controller Based Visible Spectrophotometer - Type 104
Make : Systronics
Model : Type 104
Features:
High accuracy and reliability
%T, Abs, Conc. measuring modes
Single Position 20/50 mm Cuvette Holder [Optional]
Wavelength Range |
340-960 nm |
Optical System |
Single Beam |
Mobility |
Bench-top |
Spectral Bandwidth |
10 nm |
Application |
Laboratory Use |
Brand |
Systronics |
Model No / Item Code |
104 |
Wavelength Accuracy |
+-5.0 nm |
Wavelength Repeat-ability |
5 nm |
Photo-metric Accuracy |
+-0.005 Abs |
Photo-metric Range |
0.1%T,0.001Abs |
Photo-metric Repeatability |
0.1 % T |
Detector |
Silicon Photodiode |
Lamp Type |
Tungsten Halogen Lamp |
Grating |
600 line / mm |
Display |
4 Digit Seven Segment LED |
Dimensions |
420 * 310 * 125 mm |
Material |
Fiber / Plastic |
Power |
230 V +_ 10%, AC 50 Hz |
Voltage |
230 V |
Frequency |
50 Hz |
Weight |
6.5kg |
Country of Origin |
Made in India |
View Complete details
Product Brochure
Wavelength Range | 340-3960 nm |
Optical System | Single Beam |
Mobility | Benchtop |
Spectral Bandwidth | 10 nm |
Brand | Systronics |
Model No / Item Code | Model 105 |
Wavelength Repeatability | +-5.0 nm |
Lamp Type | Tungsten Halogen Lamp |
Country of Origin | Made in India |
Digital Visible Spectrophotometer - Type 105
Make : Systronics
Model : Type 105
Features:
High accuracy and reliability
%T, Abs, Conc. measuring modes
Single Position 20/50 mm Cuvette Holder [Optional]
Wavelength Range |
340-960 nm |
Dimension |
420[W]*310[D]*125[H]nm |
Pixel Density |
+_0.005 Abs at 1.000 Abs |
Spectral Bandwidth |
10 nm |
Machine Type |
Portable |
Resolution |
0.1%T,0.001 Abs |
Shape |
Rectangle |
Display Technology |
Manual |
Lighting Type |
LED |
Display |
4 Digit Seven Segment LED |
Application |
Laboratory Use |
Brand |
Systronics |
Model No / Item Code |
105 |
Wavelength Accuracy |
+-5.0 nm |
Wavelength Repeatability |
5 nm |
Photometric Accuracy |
+-0.005 Abs |
Photometric Repeatability |
0.1 % T |
Detector |
Silicon Photodiode |
Lamp Type |
Tungsten Halogen Lamp |
Grating |
600 line / mm |
Dimensions |
420 * 310 * 125 mm |
Voltage |
230 V |
Frequency |
50 Hz |
Weight |
6.5kg |
View Complete details